Black Box ACXC32, ACXC48 Power Supply Units Malfunction, Network Error, ServSwitch DKM FX Failure

Models: ServSwitch DKM FX and DKM FX Compact ACXC32 ACXC48 ACXC16

1 184
Download 184 pages 39.34 Kb
Page 174
Image 174

Chapter 7: Troubleshooting

7.4 Power Supply Units Malfunction

Table 7-4. Power supply units malfunction.

Problem

Possible Cause

Solution

 

 

 

ServSwitch DKM FX cannot be started

Power supply units not locked

Check the power supply unit’s lock and

correctly

plug-in

 

 

No power supply is available

Check that cables for the power supply

are connected correctly

 

 

 

Power supply units are not

Check the slide to switch on the power

switched on

supply units

7.5 Network Error

Table 7-5. Network error.

Problem

Possible Cause

Solution

 

 

 

Network settings are not resumed after editing

ServSwitch DKM FX restart is not

Restart the unit

yet completed

 

7.6 ServSwitch DKM FX Failure

Table 7-6. ServSwitch DKM FX failure.

Problem

Possible Cause

Solution

 

 

 

Serial control is impossible

CPU and ServSwitch DKM FX

Adapt the baud rate in the

are running at a different baud

ServSwitch DKM FX and in the

or restricted

rate

CPU

 

 

 

 

Serial control via the RJ-45

Wrong network cable

Use a cross-pinned network cable

port is not possible

 

 

Port definitions as USB 2.0 invalid

ServSwitch DKM FX restart not

Restart the ServSwitch DKM FX

yet completed

 

Page 174

724-746-5500 blackbox.com

Page 174
Image 174
Black Box ACXC32, ACXC48, ACXC16 manual Power Supply Units Malfunction, Network Error, ServSwitch DKM FX Failure