Black Box LR5200A-R2 V.35 Null-Modem Cable Configuration, Figure D - 10 V-35 Null-Modem Cable

Models: LR5200A-R2 LR5100A-T

1 98
Download 98 pages 58.8 Kb
Page 95
Image 95
V.35 Null-Modem Cable Configuration

Interface Pinouts

V.35 Null-Modem Cable Configuration

DB25 MALE

 

 

 

 

DB25 MALE

1

Protective GND

 

 

Protective GND

1

9

Transmitted Data (A)

 

 

Received Data (A) 11

10

Transmitted Data (B)

 

 

Received Data (B) 12

11

Received Data (A)

 

 

Transmitted Data (A)

9

12

Received Data (B)

 

 

Transmitted Data (B) 10

18

Transmitter Signal Element Timing (A)

Receiver Signal Element Timing (A) 14

19

Transmitter Signal Element Timing (B)

Receiver Signal Element Timing (B) 16

14

Receiver Signal Element Timing (A)

Transmitter Signal Element Timing (A) 23

16

Receiver Signal Element Timing (B)

Transmitter Signal Element Timing (B) 25

23

Transmitter Signal Element Timing (A)

Transmitter Signal Element Timing (A) 18

25

Transmitter Signal Element Timing (B)

Transmitter Signal Element Timing (B) 19

20

Data Terminal Ready

Data Channel Received Line Signal Detector (CD)

8

8

Data Channel Received Line Signal Detector (CD)

Data Terminal Ready 20

7

Signal Ground

 

 

Signal Ground

7

4

Request to Send

 

 

Data Set Ready

6

6

Data Set Ready

 

 

Request to Send

4

Figure D – 10 V-35 Null-Modem Cable

The connecting cable must be a shielded cable.

Circuits which are paired (contain an (A) and (B) reference) should be connected to twisted pairs within the connecting cable.

This cable is needed when it is necessary to connect two units back-to-back and a set of modems is not available. Note that this cable specifies DB25 connectors on each end to allow direct connection to the link interface connector on each unit.

The link speed must be defined for each of the two units.

87