PQ-8P, PQ-8S

7.5 Problem Resolution Guide

Table 7-2is a general guide to resolve common problems that may occur. Please refer to this guide before contacting technical support.

Table 7-2. Problem Resolution Guide.

Problem or Message

Probable Cause

Action

 

 

 

Host Line Sync LED

Host is not

Make sure the host is

is not on when

configured for a printer

properly configured for the

connected to the host

at the address specified

printer.

 

 

 

 

Host is not operating

Check host system.

 

 

 

 

Damaged or improper

Check host cabling for

 

cabling

damage or improper

 

 

connection.

 

 

 

 

Twinax cable

Make sure the prior device

 

improperly terminated

is not terminated (some PC

 

 

emulator cards may terminate

 

 

mid-line).

 

 

 

 

Twisted pair cabling

Activate Star Panel Overdrive

 

is not attached to an

(front panel or host/PC

 

“active” or boosted

download command 20).

 

hub

 

 

 

 

Host Line Sync LED

Address conflict with

Make sure no other devices

blinks on and off

another twinax device

on this cable have the same

 

on the cable

address.

 

 

 

127

Page 126
Image 126
Black Box PQ-8S, PQ-8P manual Problem Resolution Guide, Probable Cause Action

PQ-8P, PQ-8S specifications

The Black Box PQ-8S and PQ-8P are advanced power quality analyzers designed for professionals seeking to monitor, analyze, and improve the electrical efficiency of their systems. These devices stand out in the market due to their robust features, sophisticated technology, and user-friendly interface, making them essential tools for electrical engineers and facility managers.

One of the standout features of the PQ-8S and PQ-8P is their ability to conduct precise power quality monitoring. Both models are equipped with high-resolution sampling rates, allowing for accurate capture of transient events and fluctuations in power quality. This capability is crucial for diagnosing issues such as voltage sags, swells, interruptions, and harmonics, which can lead to equipment malfunction or failure if left unchecked.

The PQ-8S is tailored for three-phase systems, making it ideal for industrial applications that require comprehensive analysis of three-phase power flows. Meanwhile, the PQ-8P, designed for single-phase applications, is particularly useful in residential or light commercial settings. Each model features an intuitive touchscreen interface, enabling users to navigate through data and settings effortlessly.

Data logging and extensive reporting are central to both models. They can store multiple parameters, such as voltage, current, and frequency, for prolonged periods, which assists in trend analysis and long-term monitoring. The onboard memory capacity allows users to access historical data for thorough evaluations and audits without requiring constant device connection.

In addition to their analytical prowess, the PQ-8S and PQ-8P emphasize safety and compliance. Both devices are designed with safety features that adhere to international standards, ensuring reliable performance in various environments. Their rugged design makes them suitable for both fieldwork and permanent installations, as they can withstand harsh conditions.

Wireless connectivity options enhance their usability, allowing for remote monitoring and real-time analysis from any location. This feature ensures that issues can be addressed promptly, leading to improved operational efficiency and reduced downtime.

In conclusion, the Black Box PQ-8S and PQ-8P power quality analyzers offer an impressive combination of features, advanced technologies, and practical characteristics. Their design and functionality make them indispensable tools for anyone looking to maintain optimal power quality in their electrical systems, thus ensuring reliability and efficiency in an increasingly electrified world.