COMMAND 50: SHARING PORT TIMEOUT
Selects the sharing port timeout value. This is the time interval before the interface automatically switches from the parallel or serial sharing port to check for data from the host.
VALUE | DESCRIPTION |
4 to 60 | 4 to 60 seconds |
*8 | Default |
Example: &%Z50,10 sets the time interval to 10 seconds.
COMMAND 56: PARALLEL PORT INITIALIZATION STRING
Allows the user to define a parallel- port initialization string of up to 25 ASCII bytes, which is stored in the memory of the interface card. The string is sent to initialize the printer for
5.3for more information.
VALUE | DESCRIPTION |
1(up to 25 | Defines the init |
hex bytes) | string |
1() | Deletes init string |
Example: &%Z56,1() deletes the hex strings previously defined as the
COMMAND 58: SERIAL PORT INITIALIZATION STRING
Allows the user to define a
VALUE | DESCRIPTION |
1(up to 25 | Defines the init |
hex bytes) | string |
1() | Deletes init string |
Example: &%Z58,1() deletes the hex strings previously defined as the serial port initialization string.
COMMAND 76: SERIAL-IN BAUD RATE
Selects the Baud Rate for data received at the
VALUE DESCRIPTION
038,400 baud
119,200 baud
*2 | 9,600 baud |
34,800 baud
42,400 baud
51,200 baud
6600 baud
7300 baud
Example: &%Z76,0 sets the receiving baud rate to 38,400
43