RS-232485/422 CONVERTERS

Table 2. DTE Jumper Settings.

NOTE

For additional information on the jumper requirements, see Section 3.1.

Function

Jumper Requirements

 

 

 

1.

Configure RS-232 port as DTE

XW1 in B position

 

 

 

2.

Signal ground connected to

 

 

frame ground

 

 

 

 

 

• Connected

W7 is IN (100-ohm, 1/2-watt

 

 

resistor soldered in place)

 

 

 

 

• Not connected

W7 is OUT

 

 

 

3.

Half- or full-duplex operation

 

 

• Full duplex

W8 in FULL position (4 wire, A-B)

 

 

 

 

Half-duplex

W8 in HALF position (2 wire, B-C)

 

 

 

4.

CTS delay

CTS not supported

 

 

 

5.

Enable RS-485 driver

 

 

a. RS-485 driver enabled by

W15 in A-B position and

 

RS-232 lead CD

W9 in 0-ms position

 

 

W9 in 10-ms position

 

 

W9 in 30-ms position

 

 

 