Chapter 4: Software Setup
4. Software Setup
The LES301A Ethernet Serial Server is shipped with default settings shown in Table
| Table |
|
|
Property | Default value |
|
|
IP address | 10.0.50.100 |
|
|
Gateway | 10.0.0.254 |
|
|
Subnet mask | 255.255.0.0 |
|
|
User name | admin |
|
|
Password | Null (leave it blank) |
|
|
COM 1 | 9600, None, 8, 1, No flow control, buffer disabled, packet delimiter timer 2 ms |
|
|
Link 1 | Type: TCP server, listen port 4660, filter=0.0.0.0, virtual COM disabled |
|
|
SysName of SNMP | name |
|
|
SysLocation of SNMP | location |
|
|
SysContact of SNMP | contact |
|
|
4.1 Configuration by SerialManager
4.1.1 Static IP
Use SerialManager that’s included on the product CD to configure the LES301A’s network parameters. Click on the “Configuration” button (see Figure
Figure