Black Box 1-Port 10/100 Device Server Software Setup, Configure the LES301A as a TCP Client, Page

Models: RS-422 RS-485 1-Port 10/100 Device Server RS-232

1 68
Download 68 pages 25.69 Kb
Page 23
Image 23
4.2.5 Configure the LES301A as a TCP Client

Chapter 4: Software Setup

Figure 4-11. Link Mode—TCP server setup.

4.2.5 Configure the LES301A as a TCP Client

1.Type “2” at the “Input choice (1–5) and enter:“ prompt (see Figure 4-11)

2.Input the destination IP in the “Please input Destination IP:” prompt.

3.Input the destination port in the “Please input Destination port:” prompt.

Type “1” for Connected always:

1.Double-click the “Enter” key.

2.Input idle time at the “Please input idle time to send TCP alive packet(4*10sec):” prompt. (If you input “2”, the sending TCP keep alive packet period will change to 2*10 sec)

Type “2” for Trigger by receiving COM port data:

1.Input the idle time to disconnect at the “Please input idle time to disconnect (0 sec , 1–255):” prompt. (If you input “0” disable the function; if you input “2”, the serial Inactivity beyond 2 sec will cause the unit to disconnect.)

2.Input the error retrying time in the “Please input waiting time for error retrying (0 minute, 1–255):” prompt. (If you input “0”, the function is disabled; if you input “2”, the serial Inactivity beyond 2 sec will cause the unit to disconnect.)

3.Double-click the “Enter” key.

4.Input the idle time at the “Please input idle time to send TCP alive packet(4*10sec)” prompt. (If you input “2,” the sending TCP keep alive packet period will change to 2*10 sec.)

LES301A user manual

724-746-5500 blackbox.com

Page 23

 

 

Page 23
Image 23
Black Box 1-Port 10/100 Device Server, RS-422, RS-232, RS-485 Software Setup, Configure the LES301A as a TCP Client, Page