A.2 Critical Issues of Upgrading

Appendix A: Upgrade System Firmware

Figure A-3. Download finished screen.

A.2 Critical Issues of Upgrading

1.You can abort the upgrading process by pressing the “Esc” key on the host PC during the upgrading process. The LES301A will restart automatically, and the system remains intact.

2.If the LES301A does not receive any upgrading data within 30 seconds, it will restart automatically and the system will remain intact.

3.After the upgrading process finishes, the LES301A will program the flash memory, and the buzzer will beep 6 times, then restart. Normally, it takes about 10 seconds to complete the programming process. If an error occurs during the programming process, the LES301A will clear the corresponding memory, and the system remains intact.

A.3 Error Messages

A firmware upgrade may not be successful if errors occur during the process.

 

 

Table A-1. Firmware upgrade errors.

 

 

 

 

 

 

 

 

Error cause

Message

 

 

 

 

 

 

 

 

 

Hex file text error

 

 

 

Illegal hex file format

Hex file checksum error

 

 

 

Hex file format error

 

 

 

 

 

 

 

 

Hex File end-of-record error

 

 

 

 

 

 

 

 

 

LES301A ACK start address error

 

 

 

LES301A handshaking problem

LES301A ACK length error

 

 

 

 

LES301A response command error

 

 

 

 

 

 

 

 

Configuration file

Remote IP not found

 

 

 

Open configuration file failure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 