Connection

Carry out the connection to the gas plant only by means of a rigid metallic pipe conforming to the regulations in force.

The joint for the entry of gas into the appliance is threaded GJ 1/2".

Carry out the connection avoiding any type of stress on the appliance.

Natual gas appliances must be fitted with a pressure regulator and be installed at the inlet connection. The gas pressure must then be set as a part of the commissioning procedures.

For U-LPG the pressure adjustment is made via the regulator fitted at the domestic cylinder.

Important

Upon completion of installation, always check:

λthat all the joints are completely sealed by using a soapy solution, never a flame;

λthat the gas pressure has been regulated to 1.00kPa for Natural Gas and 2.75kPa for Universal-LPG. The pressure test point is located on the regulator for Natural Gas models or at the top left hand rear of the cooker for U-LPG models. The pressure should be measured and adjusted with the Wok burner on high flame;

λthat the automatic ignition system is operating satisfactory on all burners, both individually and in combination;

λthat the burners operate correctly, are stable, without yellow tipping or excessive noise on high and low flame.

Then demonstrate to the customer the appiance operation and leave these instructions.

24

Page 24
Image 24
Blanco BC 75 X manual Connection