Installation
Electrical Connection
Before making any electrical connections to this unit, check that the power supply is adequate for the voltage, amperage, and phase requirements stated on the rating plate.
A wiring diagram accompanies this manual and is also attached to the inside of the control box.
U.S. and Canadian installations
General export installations
The export models are available in either single or three phase. The single phase oven is equipped for operation on 220, 230 or 240 VAC, 50HZ., 2 wire grounded circuits. The three phase units are equipped for operation on 400 VAC, 50HZ, 4 wire grounded circuits. Wiring from the power source to any of these units must be a minimum of #10 AWG (5.26 mm2) copper stranded wire or larger.
WARNING!!
Incorrect single phase wiring will result in extensive damage to electrical components and possible fire in the control box.
THE BLODGETT OVEN COMPANY CANNOT ASSUME RESPONSIBILITY FOR LOSS OR DAMAGE SUFFERED AS A RESULT OF IMPROPER INSTAL- LATION.
| L1 |
|
|
Supply | L2 | 208/240 | Oven |
|
|
U.S. and Canadian Installations
| L1 |
|
| |
Supply | L2 | 220/230/240 | Oven | |
|
| |||
| Single Phase Ovens |
| ||
| L1 |
|
| |
| L2 | 400 |
| |
Supply | L3 | Oven | ||
|
Three Phase Ovens
General Export Installations
Figure 9