SERVICE CONNECTION

SERVICE CONNECTION

ELECTRICAL CONNECTION: Ø1 1/8" hole for electrical connection. Rating to be as specified on data plate.

DRAIN: 1"IPS to open floor drain. No solid connection. 24" length before open air gap opening (No bends or elbows).

GENERATOR WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa)

CCONDENSING WATER: 3/8" O.D. tubing at 25-50 PSI(170-345 kPa)

WATER QUALITY STATEMENT

WATER QUALITY IS THE MAJOR FACTOR AFFECTING THE PERFORMANCE OF YOUR APPLIANCE. IF YOU ARE UNSURE OF WATER QUALITY, CONSULT A LOCAL WATER TREATMENT SPECIALIST AND HAVE THE WATER ANALYZED. YOUR WATER SUPPLY MUST BE WITHIN THESE GENERAL GUIDELINES:

TOTAL DISSOLVED SOLIDS

LESS THAN 60 PPM

TOTAL ALKALINITY

LESS THAN 20 PPM

SILICA

LESS THAN 13 PPM

CHLORINE

LESS THAN 1.5 PPM

pH FACTOR

7.0-8.5

WATER WHICH FAILS TO MEET THESE STANDARDS SHOULD BE TREATED BY INSTALLATION OF A WATER CONDITIONER. FAILURE OR MALFUNCTION OF THIS APPLIANCE DUE TO POOR WATER QUALITY IS NOT COVERED UNDER WARRANTY.

 

 

ELECTRICAL CHARACTERISTICS

 

 

 

 

 

 

MODEL

kW

Phase

 

 

 

 

AMPS PER LINE

 

 

 

 

208V

220V

240V

380V

415V

480V

 

600V

 

 

 

 

SN-3E standard

7.5

1

36

34

31

n/a

n/a

n/a

 

 

n/a

 

 

3

21

20

18

11

10

9

 

 

7

SN-3E option

10

1

48

46

42

n/a

n/a

n/a

 

 

n/a

 

 

3

28

26

24

15

14

12

 

 

10

SN-5E standard

15

1

72

68

63

n/a

n/a

n/a

 

 

n/a

3

 

 

 

 

 

 

 

 

 

 

 

42

39

36

23

21

18

 

 

14

 

 

 

17 [432]

 

 

27.5 [698]

 

1.75 [45]

 

 

 

 

 

 

 

1.13 [29]

 

 

 

 

DIMENSIONS ARE IN INCHES [MM]

 

 

 

 

 

 

3 [76]

1.75 [45]

15 [381]

24 [610]

 

 

 

 

 

 

 

 

 

 

 

SN-3E

SN-5E

1.5 [38]

12.5 [318]

19 [483]

20 [508]

 

 

1/2-NPT DELIME INLET

 

SN-3E

SN-5E

 

 

 

1 [25]

15.12 [384]

21.62 [549]

OPTIONAL LEGS

 

 

 

 

4 [102]

 

23.5 [597]

2 [51]

 

 

4