Blodgett SN-3E, SN-5E manual 6.0ADJUSTMENT FOR HIGH ALTITUDE LOCATIONS

Models: SN-3E SN-5E

1 17
Download 17 pages 2.72 Kb
Page 15
Image 15
6.0ADJUSTMENT FOR HIGH ALTITUDE LOCATIONS

7.FLUSH CYCLE: Turn main power switch to ON. When READY light comes on, turn main power switch to OFF to flush generator. Repeat this step three times to completely flush generator.

8.Clean exterior and interior. Use a mild solution of soap and water. Rinse with clean cloth. Dry with soft cloth. Leave compartment door open when not in use.

The steamer is now ready for use. Turn off for overnight shutdown.

6.0ADJUSTMENT FOR HIGH ALTITUDE LOCATIONS

The steamer has been factory set so that when it is ON and during the READY phase, it will maintain water temperature in the steam generator tank at approximately 205 degrees Fahrenheit (just below water boiling point). However, for high altitude locations, an authorized servicer must adjust the steamer to achieve this temperature. To adjust:

1.Remove side panel and turn control panel power switch to ON.

2.Open compartment door, and after about 15 minutes, steam will be seen, entering the cooking compartment.

3.Turn thermostat shaft counterclockwise to lower temperature until steam just ceases to enter cooking compartment and READY light goes on.

4.Replace side panel.

5.Follow TESTING PROCEDURES in this manual.

15

Page 15
Image 15