2.0 TESTING PROCEDURES

2.0 TESTING PROCEDURES

WARNING: The steamer and its parts are hot. Use care when operating, cleaning or servicing the steamer. The cooking compartment contains live steam. Stay clear while opening door.

Once the steamer is installed and all mechanical connections have been made, thoroughly test the steamer before operation.

1.Check that proper water, drain and electrical connections have been made.

2.Turn main power switch ON. After approximately 15 minutes, the READY light should come on, indicating that the water temperature is 205 degrees Fahrenheit.

3.When the READY light comes on, set timer to the “5 minute” position. With door open, observe that no steam is entering the compartment and that the COOKING light is OFF.

4.Close compartment door. The COOKING light should now be illuminated and steam should be heard entering the compartment after about 45 seconds.

5.Check drain line to ensure that water from cold water condenser is flowing through the drain line.

6.Open compartment door and observe that steam supply to chamber is cut off (READY light should again come on as COOKING light goes off.

7.Close compartment door and let cooking cycle finish. When the timer returns to “0" position, a buzzer will sound signalling the end of the cooking cycle. Buzzer must be manually turned off by setting the timer to its OFF position.

8.To shut down steamer, turn main power switch OFF and leave compartment door slightly open.