SERVICING INSTRUCTIONS (continued)
REPLACE SOLENOID
Symptom: Automatic brewer will not flow water; or, automatic brewer drips continuously from brew head.
NOTE: Wrench p/n 86660 is designed to allow easy removal of the hoses from the plastic solenoid valve.
IMPORTANT:
Remove top cover and detach solenoid access door from cabinet.
Remove faucet tube from faucet valve at flare fitting. Remove water supply flare fitting:
a.Slide the 5/8" end of the wrench over the flats on the inlet fitting of the valve.
b.Hold the wrench to prevent the inlet fitting from turning while installing or removing the inlet water supply flare nut.
Remove faucet tube from solenoid:
a.Slide the 7/16" end of the wrench between the valve body and the white ring on the extreme end of the metal hose fitting.
b.Pressure on the white ring toward the metal fitting releases the clinch ring, allowing the tube to be easily slid off of the solenoid bypass outlet.
c.Install tube on new valve by pressing end of tube onto bypass outlet until it is fully seated.
Disconnect wiring.
Remove two screws holding solenoid to access door. Reassemble in reverse order.
Fig. 10 Remove Faucet Supply from Solenoid
685 77110 Owners Manual Horizon™ Brewers
CLEAN SOLENOID SCREEN |
|
Symptom: Automatic brewer will not flow water. |
|
Disconnect brewer from electric power. Turn OFF and |
|
disconnect water supply from brewer inlet fitting. |
|
Unscrew water inlet fitting from solenoid. |
|
Using |
|
Clean screen under faucet. A stiff bristle brush may be used if |
|
necessary. |
|
Reinsert screen in solenoid. Be careful to maintain correct | Fig. 11 Clean Strainer Screen |
orientation. (The OPEN END of the screen goes in FIRST.) | |
Reassemble in reverse order. |
|