TROUBLESHOOTING SUGGESTIONS

685 77110 Owners Manual Horizon™ Brewers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TROUBLESHOOTING SUGGESTIONS

 

 

 

 

SYMPTOM

POSSIBLE CAUSE

SUGGESTED REMEDY

 

 

 

 

 

 

 

 

 

 

Water won’t heat

Brewer unplugged or circuit

Check power supply cord

 

 

 

 

 

breaker tripped

Check / reset circuit breaker

 

 

 

 

 

 

 

 

 

 

 

 

Temperature setpoint too low

Set for desired temperature

 

 

 

 

 

 

 

 

 

 

 

 

Hi-Limit safety switch tripped

Allow to cool hi-limit will self-

 

 

 

 

 

 

 

 

reset

 

 

 

 

 

 

 

 

 

 

 

 

Damaged internal component

Examine wiring & connectors,

 

 

 

 

 

or wiring

thermostat and heating element

 

 

 

 

 

 

 

 

Repair/replace as needed

 

 

 

 

 

 

 

 

 

 

Coffee level too high or low

Timer out of adjustment

Adjust timer

 

 

 

 

 

 

 

 

 

 

Brew chamber overflows

Too many filter papers or wrong

Use one (1) genuine Bloomfield

 

 

 

 

 

filter paper

filter per brew

 

 

 

 

 

 

 

 

 

 

 

 

Brew chamber dispense hole

Thoroughly clean brew

 

 

 

 

 

plugged

chamber

 

 

 

 

 

 

 

 

 

 

 

 

Too much coffee or too fine a

Use correct grind and amount

 

 

 

 

 

grind

of coffee

 

 

 

 

 

 

 

 

 

 

Sprays water from brew head

Spray gasket improperly

Check/reinstall gasket on

 

 

 

 

 

installed

INSIDE of brew head

 

 

 

 

 

 

 

 

 

 

No brew (faucet flows OK)

Spray disk plugged

Clean spray disk

 

 

 

 

 

 

 

 

 

 

 

 

Damaged internal component

Check brew switch, timer,

 

 

 

 

 

or wiring

controller, solenoid and wiring

 

 

 

 

 

 

 

 

Repair, replace as needed

 

 

 

 

 

 

 

 

 

 

No brew plus no flow from hot

Water supply OFF

Turn water supply ON

 

 

 

water faucet

 

 

 

 

 

 

 

 

 

 

Solenoid inlet strainer plugged

Clean strainer

 

 

 

 

 

 

 

 

 

 

 

 

Water filter (if used) plugged

Replace filter element

 

 

 

 

 

 

 

 

 

 

No flow from hot water faucet

Faucet valve turned OFF

Turn faucet valve ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Poor coffee quality

Keep brewer, decanters and airpots clean.

 

 

 

 

 

 

 

 

 

 

Install a taste and odor filter in water supply, and replace

 

 

 

 

 

cartridges regularly.

 

 

 

 

 

 

 

Use a quality coffee with a consistent roast. Use proper grind

 

 

 

 

 

and amount of coffee per brew.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 