SERVICING INSTRUCTIONS

SERVICING INSTRUCTIONS

CAUTION:

ACCESS PANELS

SHOCK HAZARD

WARMER PLATES:

 

Opening access panels or removing warmer plates on this brewer may expose uninsulated electrical components. Disconnect brewer from electrical power before removing any panel

Trouble shooting guides, component views and parts lists are included for general reference, and are intended for use by qualified service personnel..

Warmer plates unscrew counter-clockwise.

TOP PANEL:

Remove top panel to access hot water tank, thermostat, heating elements, brew circuit tubing, faucet valve and piping, and top- mounted warmers.

Top panel is held by screws around the edge.

FRONT PANEL:

Remove front panel to access timer.

Models 0412 and 0443:

Front panel and main warmer panel are one piece, and are held by screws around the edge and a retaining lip at the top.

Models 0471 and 0472:

Front panel and main warmer panel are one piece, and are held by screws around the edge and a retaining lip at the top and at the rear warmer plate panel. This panel is secured to the cabinet by the warmer plate.

Model 0482:

The front panel is held by two screws at the bottom and a retaining lip at the top.

SOLENOID DOOR:

Remove solenoid door to access solenoid plumbing connections. Solenoid door is held by two screws and a retaining lip.