DESCRIPTION OF PROBLEM
No lights or heat
No heat
Brewer overflows
Brew chamber overflows
Heats slow
Slow to fill
Satellite does not heat
Satellite shorts out
Poor coffee quality
TROUBLESHOOTING SUGGESTIONS | |
POSSIBLE CAUSE | SUGGESTED REMEDY |
Unit not plugged in or circuit | Reset circuit breaker |
breaker tripped | Plug brewer into electric power |
Power switch OFF | Turn power switch ON |
Allow brewer to cool, verify water | |
| level, reset |
Water level probe corroded | Clean water level probe |
Poor ground connection | Verify ground connection |
Dirt in inlet valve or valve | Replace inlet valve |
damaged |
|
Brew valve damaged | Replace brew valve |
Too many paper filters or wrong | Use one genuine Bloomfield |
filter used. | paper filter per brew |
Chamber discharge hole | Clean brew chamber |
plugged |
|
Improper programming | Correct program (see pg. 12) |
Connected to wrong voltage | Verify supply voltage |
Scale | |
elements |
|
Damaged heating element | Replace element |
Insufficient water pressure | Brewer must be operated on a |
| dedicated water line. Other |
| equipment on line may be |
| robbing water volume. |
Plugged water line strainer | Clean strainer |
Not properly seated | Seat satellite in receptacle |
Fuse blown | Correct problem, replace fuse |
Damaged satellite receptacle or | Determine/repair damage to |
wiring | satellite |
Damaged brewer receptacle | Repair/replace receptacle |
Wet insulation | Disassemble satellite, allow |
| to dry completely before |
| reassembly |
Improper programming | Correct programming |
Also:
Keep brewer and servers clean.
Install a taste and odor filter in water supply, and replace cartridges regularly.
Use a quality coffee with a consistent roast. Use proper grind and amount of coffee per brew.
17