OPERATING INSTRUCTIONS
Fig. 3 Control Panel
GETTING STARTED
Check the brewer and satellites:
Check that the brewer is clean and the drip tray (if used) is empty.
Check that the satellites are empty and clean with lids properly installed.
Check the spray heads:
Remove the brew chambers. Check the spray heads. Verify that the spray disks are clean and properly installed. Verify that the gaskets are properly installed inside the spray heads.
Check the brew chambers:
Check that the brew chamber is clean.
Check that the wire basket is properly installed in the brew chamber.
DAILY START-UP
Press system switch (back of brewer, lower right corner) to ON:
Brewer will “beep” and briefly display the message
BLOOMFIELD.
Press POWER KEY to enter ON mode:
Brewer water tank will begin filling. The message FILLING will be displayed.
When the tank is full, TANK HEAT LED will glow, and the message HEATING is displayed indicating that the tank heater is ON.
Press WARMER SWITCHES to OFF until you are ready to begin a brew.
When the tank is filled and up to temperature, time and date are displayed. The brewer is ready to operate.
NOTE:
If water is not sensed at the water level sensor within 20 minutes:
Heater will be disabled Error message NO WATER SENSED will be displayed
Call the PHONE NUMBER displayed for service.
7