Specifications are subject to change. See bluesea.com/P12 for current information.

1. Charging:

SOLID ON (Green): Indicates Charging mode and will operate according to its charging stage.
BLINKING (Green): Transitioning from Standby to a Charging state.
OFF: Standby mode - will not charge a battery or supply current to loads.

2. Charge Stage:

Bulk - BLINKING (Green): Indicates Bulk stage on all batteries
Absorb - BLINKING (Green): Indicates Absorb stage on all batteries
Prefloat*- SOLID ON (Green): Indicates PreFloat stage on any of three batteries
Float - SOLID ON (Green): Indicates Float stage on all batteries
Equalize - BLINKING (Yellow): Indicates Equalize stage on any of three battery branches.

3. Fan Mode:

SOLID ON (Green): Indicates fan LOW or HIGH mode.
SOLID ON (Yellow): Indicates fan OFF mode.
BLINKING (Yellow): Indicates that the fan is OFF and the charger is limiting its output current to protect from eventual overheating. If full output is desired, the
Fan Mode needs to be set to LOW or HIGH to keep the charger cool. If the fan is OFF the charger will limit its output based on its internal temperature sense.

4. Charge Output:

SOLID ON (Green): Charge Output LEDs are used to monitor the output on three batteries and limit the output using the output button. In normal operation, the Charge
Output LEDs show the percentage of the absolute maximum current on each battery. The range of each individual percentage is as follows:
<5%: 0% ≥ output < 5%
10%: 5% ≥ output < 17.5 %
25%: 17.5% ≥ output < 37.5%
50%: 37.5% ≥ output < 62.5%
75%: 62.5% ≥ output < 87.5%
100%: 87.5% ≥ output < 100%
BLINKING (Green): Indicates that the charger is limiting its output. There are two situations where this could occur:
1) The output of the charger is being limited per the user’s output setting.
2) The charger is limiting output to protect itself from overheating. In this situation, the Charge Output will blink alongside the yellow Thermal Regulation Alert.
P12
7520 BATTERY CHARGER REMOTE
Charge Output
OUTPUT
CHARGING
Charge Stage
BULK
ABSORB
PREFLOAT
FLOAT
EQUALIZE
HIGHLOWOFF
Fan Mode
DIM /
123
100%
75%
50%
25%
10%
<5%
QuickGuide
Alert
AC
123
DC
1. Charging
2. Charge Stage
BULK
ABSORB
PREFLOAT
FLOAT
EQUALIZE
3. Fan Mode
4. Charge Output
5. Thermal Regulation and
6. Internal Temperature Sensor
7. Battery Temperature Sensor
8. Fan
9. DC Fuse
10. AC Input Voltage
Too High or Low
11. Reverse Polarity
or Short Circuit
12. Hardware Failure,
DC Output Voltage Too High,
or Equalization Overload
13. Fan Mode
14. DIM/Alarm
15. Output
16. Standby

Display Indicators

26
P12
7520 BATTERY CHARGER REMOTE