10 en Configuration | IVMD Configuration instructions |
|
|
3.1VCA tab (Video content analysis)
The camera image appears on the right. You see an individual image that is refreshed at regular intervals. As soon as the analysis is activated, meta data is generated and depending on the configuration the additional information is overlaid on top of the image – an object bounding box for example.
1.Move the camera to the required position.
NOTE!
iAll of the settings you make relate to the selected camera posi- tion. This means that you must reconfigure IVMD for this cam-
era whenever you change the camera's direction or position.
2.Activate the analysis. Otherwise alarm events are not out- put for further processing.
3.Select IVMD 1.0 under Analysis type.
4.If you are configuring IVMD for a camera for the first time, select suitable initial settings for all parameters by clicking Default settings. You should also do this if you have changed the camera's position or direction.
5.Click Select area...
The Area settings window opens. IVMD is configured using this window.
You will find full details in the next section.
1.0 2006.04 | BOSCH Security Systems |