14 en Area settings | IVMD Configuration instructions |
|
|
Calibration
If you wish to filter out objects according to their size or speed, for each camera position a link must be made between the size of the
50 pixels is around 2 m high in reality. The camera angle is used to compute object speeds. The calibration mode is available for this operation.
NOTE!
Display of measurements can be adjusted, so that when using i the English software interface imperial measurements are
shown. You will find additional information in Section 5 Display of Measurements, page 38.
Filter hierarchy
Below is an overview of the filter methods. You will find a description of the filters in the following sections.
Sensitive area | Objects outside the sensitive area are |
| ignored. |
|
|
Global settings | Objects that are smaller than the min- |
| imum size setting or larger than the |
| maximum size setting are ignored. |
|
|
Detector field | Only objects with their center (center |
| of gravity) inside the detector field |
| are detected. |
|
|
Properties | Objects are filtered out based on |
of the detector field | their properties. Different properties |
| can be defined separately for each |
| detector field. |
|
|
1.0 2006.04 | BOSCH Security Systems |