30 en Area settingsIVMD Configuration instructions
Trigger |
|
Mode: | An alarm event is generated when... |
Entering | ...the center of the object moves across the |
| boundary of the detector field and into the |
| field. |
| Debounce time: If a value other than 0 |
| (zero) is selected, the alarm event will not |
| be generated until the center of the object |
| has fully crossed the boundary of the |
| detector field after this time. This prevents |
| objects triggering a large number of alarm |
| events when they are moving around on |
| the edge of the detector field. |
Leaving | ...the center of the object moves across the |
| boundary of the detector field and out of |
| the field. |
| Debounce time: as for entering objects, |
| see above. |
Inside | ...the center of the object moves inside the |
| detector field. |
| Delay [s]: If a value other than 0 (zero) is |
| selected, the alarm event will not be gener- |
| ated until the object has moved or been |
| inside the detector field for at least the |
| selected delay time. |
NOTE!
iIf the boundary of the detector field lies across a static object that can conceal a moving object (e.g. advertising hoarding),
entering or leaving may not be detected.