30 en Area settingsIVMD Configuration instructions

Trigger

 

Mode:

An alarm event is generated when...

Entering

...the center of the object moves across the

 

boundary of the detector field and into the

 

field.

 

Debounce time: If a value other than 0

 

(zero) is selected, the alarm event will not

 

be generated until the center of the object

 

has fully crossed the boundary of the

 

detector field after this time. This prevents

 

objects triggering a large number of alarm

 

events when they are moving around on

 

the edge of the detector field.

Leaving

...the center of the object moves across the

 

boundary of the detector field and out of

 

the field.

 

Debounce time: as for entering objects,

 

see above.

Inside

...the center of the object moves inside the

 

detector field.

 

Delay [s]: If a value other than 0 (zero) is

 

selected, the alarm event will not be gener-

 

ated until the object has moved or been

 

inside the detector field for at least the

 

selected delay time.

NOTE!

iIf the boundary of the detector field lies across a static object that can conceal a moving object (e.g. advertising hoarding),

entering or leaving may not be detected.

1.0 2006.04

BOSCH Security Systems