Bosch Appliances KTS 200 Maintenance, Technical data, 6.1Cleaning, 6.2Spare and wearing parts

Models: KTS 200

1 12
Download 12 pages 9.85 Kb
Page 12
Image 12
Maintenance  KTS 200  25

Maintenance KTS 200 25

en

6. Maintenance

7. Technical data

6.1Cleaning

The housing and the display on the KTS 200 may only be cleaned with soft cloths and with neutral cleaning agents. Do not use any abrasive cleaning agent or rough cleaning cloths.

6.2Spare and wearing parts

Description

Order number

System tester KTS 200 (green)

1 687 023 279

 

 

System tester KTS 200 (blue)

1 687 023 428

 

 

System tester KTS 200 (gray)

1 687 023 429

 

 

Power pack

1 687 023 889

Power supply lead(<)

1 684 461 106

USB connecting lead, 1 m(<)

1 684 465 491

OBD diagnostic lead, 1.5 m(<)

1 684 465 555

Wall bracket

1 681 320 082

 

 

(<) Wearing parts

7.1

General data

 

 

 

 

Property

 

Value/Range

Operating voltage

7 VDC — 34 VDC

 

 

Power consumption

approx. 7 Watt

 

 

LCD display

3,5"

 

 

320 * 240 Pixel

Dimensions (L x W x H)

140 x 220 x 40 mm

 

 

Weight (without connecting leads)

600 g

 

 

Operating temperature

5 °C – 40 °C

Relative humidity

90 % (at 25 °C)

 

 

Protection class

IP 30

 

 

 

7.2Interface protocols

The following interfaces and their associated protocols are supported for control unit diagnosis in compliance with ISO 15031:

ISO 9141-2 (communication lines K and L) SAE J1850VPW und SAE J1850PWM (communication lines BUS+ and BUS-) CAN ISO 11898 ISO 15765-4 (OBD) (communication lines CAN-H and CAN-L) CAN Single Wire

CAN Low Speed

7.3Power pack

Property

Value/Range

Input voltage

90

VAC — 264 VAC

 

 

 

Input frequency

47

Hz — 63 Hz

 

 

 

Output voltage

15

V

 

 

Operating temperature

0 °C — 40 °C

 

 

 

Bosch Diagnostics

1 689 989 001 2007-05-30