Maintenance KTS 200 25
en
6. Maintenance | 7. Technical data |
6.1Cleaning
The housing and the display on the KTS 200 may only be cleaned with soft cloths and with neutral cleaning agents. Do not use any abrasive cleaning agent or rough cleaning cloths.
6.2Spare and wearing parts
Description | Order number |
System tester KTS 200 (green) | 1 687 023 279 |
|
|
System tester KTS 200 (blue) | 1 687 023 428 |
|
|
System tester KTS 200 (gray) | 1 687 023 429 |
|
|
Power pack | 1 687 023 889 |
Power supply lead(<) | 1 684 461 106 |
USB connecting lead, 1 m(<) | 1 684 465 491 |
OBD diagnostic lead, 1.5 m(<) | 1 684 465 555 |
Wall bracket | 1 681 320 082 |
|
|
(<) Wearing parts
7.1 | General data |
|
|
|
|
Property |
| Value/Range |
Operating voltage | 7 VDC — 34 VDC | |
|
| |
Power consumption | approx. 7 Watt | |
|
| |
LCD display | 3,5" | |
|
| 320 * 240 Pixel |
Dimensions (L x W x H) | 140 x 220 x 40 mm | |
|
| |
Weight (without connecting leads) | 600 g | |
|
| |
Operating temperature | 5 °C – 40 °C | |
Relative humidity | 90 % (at 25 °C) | |
|
| |
Protection class | IP 30 | |
|
|
|
7.2Interface protocols
The following interfaces and their associated protocols are supported for control unit diagnosis in compliance with ISO 15031:
ISO
CAN Low Speed
7.3Power pack
Property | Value/Range | |
Input voltage | 90 | VAC — 264 VAC |
|
|
|
Input frequency | 47 | Hz — 63 Hz |
|
|
|
Output voltage | 15 | V |
|
| |
Operating temperature | 0 °C — 40 °C | |
|
|
|
Bosch Diagnostics | 1 689 989 001 |