24 KTS 200 Operation
5.5Software update
The software update is either performed using the “ESI[tronic] Startcenter” DVD or “online”.
The online software update (section 5.5.2) can only be performed with ESI[tronic] Startcenter version 2007/3 or later.
5.5.1Software update using the ESI[tronic]
Startcenter DVD
1.Insert the “ESI[tronic] Startcenter” DVD in the DVD drive (e.g. “D:\”) on the PC/laptop.
2.Open the “Run” input field (select “Start >> Run...” in the taskbar).
3.Enter D:\setup.exe and confirm by clicking <OK>.
?The Setup routine is started.
?Follow the installation instructions on the screen.
4.When installation is complete, restart the computer.
?Windows is shut down and ESI[tronic] Startcenter is restarted.
5.Connect the KTS 200 to the PC using the USB con- necting lead.
6.Connect the KTS 200 to the mains using the power pack supplied.
?The KTS 200 starts up.
During the software update, the USB connection and the power supply to the KTS 200 may not be broken.
7.ESI[tronic] Startcenter: Open “KTS 200 >> Device information”.
8.Select an available update.
9.Select <Update>.
GThe system software is installed on the KTS 200.
5.5.2Online software update
1.Start “ESI[tronic] Startcenter”.
2.Open the “Settings >>Online updates” input window.
3.Enter the customer number and password and select <Next>.
If “Login” is not possible, check your proxy settings under “Settings >> User settings”.
4.Select an available update and start the software update.
5.Follow the installation instructions on the screen.
6.When installation is complete, restart the computer.
?Windows is shut down and ESI[tronic] Startcenter is restarted.
7.Connect the KTS 200 to the PC using the USB connecting lead.
8.Connect the KTS 200 to the mains using the power pack supplied.
?The KTS 200 starts up.
During the software update, the USB connection and the power supply to the KTS 200 may not be broken.
9.ESI[tronic] Startcenter: “KTS 200 >> Device information”.
10.Select an available update
11.Select <Update>.
GThe system software is installed on the KTS 200.
5.6Faults
The KTS 200 may not be opened. Opening the KTS 200 erases its licensing data. It is then no longer possible to perform control unit diagnosis.
No communication with the control unit
The fault message “No system found” appears during control unit diagnosis.
Possible causes | What can you do? |
Incorrect lead | Check whether the correct |
connected. | lead has been used. |
|
|
Incorrect pin selected | Under “Start >> Diagnostic socket”, |
in pin selection menu | check which pin has to be used. |
|
|
If problems of a different nature occur, please contact the ESI[tronic] service hotline directly.
1 689 989 001 | Bosch Diagnostics |