Bosch Appliances L0609466 manual Properlysecurestrainreliefseeprevioussection, Terminal Block

Models: L0609466

1 26
Download 26 pages 10.56 Kb
Page 17
Image 17
10.Properlysecurestrainrelief(seeprevioussection).

 

Installation

 

10.Properlysecurestrainrelief(seeprevioussection).

 

Note:

 

DONOTpluginrangeatthistime.

ThreeWire Range Cord Connection

The Four Wire Connection (above) is preferred, but where local codes and ordi-

 

nances permit grounding through neutral and where conversion to four wire is

 

impractical, the unit may be connected to the power supply via a three wire con-

 

nection.

 

1. Disconnect electrical power at breaker box.

 

2. Remove the terminal block cover to expose the terminal block.

Figure 16: Terminal Block

. Remove top nut, star washer, and round washer from each post.

Note:

DO NOT remove last round washer, last nut or internal wiring leads.

4.Attach white wire, round washer, star washer and nut IN THIS ORDER on top of ground strap on center post.

5.Attach red wire, round washer, star washer and nut IN THIS ORDER to left post.

6.Attach black wire, round washer, star washer and nut IN THIS ORDER to right post.

/black

_!i_ ground strap

!ii

white

red

Figure 17: Three Wire Connection