Bosch Appliances L0609466 manual Gas Safety, Gas Precautions

Models: L0609466

1 26
Download 26 pages 10.56 Kb
Page 4
Image 4
,_Safety

,_Safety

Be sure your appliance is properly installed and grounded by a qualified tech- nician. Installation, electrical connections and grounding must comply with all applicable codes.

Gas Safety

Install

a gas shutoff

valve near the appliance.

It must be easily accessible

in

 

 

an emergency.

 

 

 

 

 

 

Leak testing must be conducted by the

installer according to the instructions

 

 

in this

manual.

 

 

 

 

 

 

The appliance and its individual shutoff

valve

must be disconnected from

the

 

 

gas supply piping system during any pressure testing at pressures in excess

 

 

of ½ psi (3.5 kPa)

 

 

 

 

 

 

The appliance must be isolated from the gas supply piping system by closing

 

 

its individual manual shutoff valve during any pressure testing of the gas sup-

 

 

ply piping system at test pressures equal to or less than ½ psi (3.5 kPa)

 

 

The minimum supply pressure must be 1" water column above the manifold

 

 

pressure printed on the data plate:

 

 

 

 

The maximum supply pressure must not exceed 14.0 inches water column

 

 

(34.9Millibars).

 

 

 

 

 

 

 

WARNING: If the information in this manual is not followed exactly, a fire or

 

 

explosion may result causing property damage, personal injury or death.

 

 

 

Do not store or use combustible materials, gasoline or other flammable

 

 

vapors and liquids in the vicinity of this or any other appliance

 

 

 

WHAT TO DO IF YOU SMELL GAS:

 

 

 

 

Do not try to light any appliance.

 

 

 

 

 

Do not touch

any electrical switch.

 

 

 

 

Do not use any phone

in your building.

 

 

 

Immediately

call your

gas supplier from a neighbor's phone. Follow

 

 

 

the gas supplier's instructions.

 

 

 

 

 

If you cannot

reach your gas supplier,

call the fire department. Instal-

 

 

 

lation and service must be performed by a qualified installer, autho-

 

 

 

rized service agency or the gas supplier.

 

Figure 1: Gas Precautions

This appliance has been CSA certified for safe operation up to a height of 10,000 ft. without any modifications. Exception: For use with propane the appliance must be converted per the LP conversion instructions.

For Massachusetts installations:

Installation must be performed by a qualified or licensed contractor, plumber or gas fitter qualified or licensed by the state, province or region where this appliance is being installed.

Shut-off valve must be a "T" handle gas cock.

Flexible gas connector must not be longer than 36 inches.

Installer - show the owner where the gas shut-off valve is located.

Propane Gas InstallationThe propane gas tank must be equipped with its own high pressure regulator. In addition, the regulator supplied with this unit must also be used.

The appliance is shipped from the factory for use with natural gas. It must be converted for use with propane. A qualified technician or installer must do the conversion.

English 2

Page 4
Image 4