DinionXF Installation Manual
EN 23
Adjustment procedure
1.Unlock the back focus locking button.
2.Adjust the lens to the maximum lens opening.
3.Turn the back focus adjustment as required.
4.Lock the back focus locking button.
Adjustment procedure
1.Unlock the back focus locking button.
2.Access the Lens Wizard menu.
3.SET BACK FOCUS NOW is highlighted in the menu.
4.Turn the back focus adjustment as required.
5.Lock the back focus locking button.
6.Select SET LVL in the menu; the LEVEL bar appears.
7.Point the camera at the scene it will be mostly viewing.
8.Adjust the level potentiometer located on the lens until the LEVEL bar is in the central position.
9.Exit the menu.
Note
The best performance with video iris lenses is obtained when the peak/ average potentiometer of the lens is set to either full average or full peak matching the position of the peak/average balance in the MODE x ALC menu.
Install I/O submenu
Function | Selection | Description |
SYNC IN | 75 Ohm, HIGH | Select 75 Ohm if the external sync input is not |
|
| terminated elsewhere. |
|
|
|
COMM | ON, OFF | If OFF, Bilinx communication is disabled. |
CABLE | OFF, DEFAULT, | Cable compensation is used to avoid the need for |
COMP | RG59, COAX12, | amplifiers in long distance coax connections up to |
| COAX6 | 1000m (3000ft). For optimum results select the |
|
| coaxial cable type used or if unknown, DEFAULT. |
|
|
|
COMP | 0, 1, .. +15 | Sets the level of cable compensation. |
LEVEL |
|
|
ALARM | Select submenu |
|
|
|
|
EXIT |
| Return to the INSTALL menu |
|
|
|
Bosch Security Systems