LTC 4600 Series Instruction Manual Troubleshooting | EN 17 |
|
|
6TROUBLESHOOTING
| Video Links: | |
|
| |
Video Problems | Verify that a valid video signal is being applied to the transmitter module. | |
| Verify the integrity of the coax connections between devices and fiber modules. | |
| Verify that the correct fiber cable is being used (i.e., multimode only). | |
| Verify that the length of the fiber optic cable and associated splices do not exceed the allowable optical | |
| loss budget. | |
Power Problems | Verify the power cable connections between modules and power pack. | |
Verify that the power pack is connected to the appropriate AC power source. | ||
| ||
|
| |
| Data Links: | |
Data Transmission | Verify the polarity of data connections between devices. | |
Problems | If data transmission is not working over the fiber link, verify that a direct connection between the | |
| associated products operates correctly. | |
| Verify the integrity of the data cable connections between devices and fiber modules. | |
| Verify that the correct fiber cable is being used (i.e., multimode only). | |
| Verify that the length of the fiber optic cable and associated splices do not exceed the allowable optical | |
| loss budget. | |
| When using LTC 4671 Series | |
| resistor. | |
Power Problems | Verify power cable connections between modules and power pack. | |
| Verify that the power pack is connected to the appropriate AC power source. | |
|
| |
| LTC 4637 Series | |
Power LED on the Power | Verify that the AC line cord is connected to an appropriate AC voltage source. | |
Supply Fails to Light | Check and/or replace the AC fuse located near the AC connector on the rear of the power supply. | |
Power LED on all | Verify that the power supply cable to the circuit board back plane (located on the rear of the card cage) is | |
Modules Fails to Light | properly connected. | |
Power LED on Individual | Verify that affected | |
Verify that fuses on the affected | ||
Light |
| |
|
|
Bosch Security Systems July 08, 2008