9Maintenance
9.1Testing the network connection
The ping command can be used to check the connection between two IP addresses. This allows testing whether a device is active in the network.
1.Open the DOS command prompt.
2.Type ping followed by the IP address of the device.
If the device is found, the response appears as " Reply from ... ", followed by the number of bytes sent and the transmission time in milliseconds. Otherwise, the device cannot be accessed via the network. This might be because:
–The device is not properly connected to the network. Check the cable connections in this case.
–The device is not correctly integrated into the network. Check the IP address, subnet mask, and gateway address.
9.2Cleaning the bubble
The exterior of the bubble is hard coated for extra protection. If cleaning becomes necessary, only use cleaning solutions and cloths suitable for cleaning safety glass lenses. Dry the bubble thoroughly with a dry nonabrasive cloth to prevent water spots. Never scrub the bubble with any abrasive material or cleaners.
–Do not use abrasive or highly alkaline cleaners on the bubble.
–Do not scrape the bubble with razor blades or other sharp instruments.
–Do not use Benzene, Gasoline, Acetone, or Carbon Tetrachloride on the bubble.
–Do not clean bubbles in the hot sun or on very hot days