Bosch Appliances NKT 72, NKT 92 Electrical Connections, FigureA, Figure B, Grounded neutral

Models: NKT 92 NKT 72

1 12
Download 12 pages 22.62 Kb
Page 10
Image 10
Electrical Connections

J

t

-i

Electrical Connections

This appliance is manufactured

with a green and

 

Cable from

yellow striped GROUND wire connected to the

 

power supply

Grounded neutral

Junction box

cook-top chassis. After making sure that the power

 

 

has been turned off connect the flexible conduit

 

 

from the cook-top to the junction box using a U.L.

Red wires

 

listed conduit connector, see figures A and B.

 

 

Figures A and B and the instructions provided

 

 

below present the most common way of

 

 

connecting the cook-tups. Your local codes and

 

 

ordinances, of course, take precedence to these

 

 

instructions. Complete electrical

connections

 

 

according to local codes and ordinances.

Twist-on connectors

3-wirebranch circuit

Refer to Figure A, where local codesallow the connection of GROUND wire to the branch circuit NEUTRAL (grey or white wire):

If local codes permit, connect the green and yellow striped GROUND wire from the cook-top to the branch circuit NEUTRAL wire (grey or white color wire).

Connect the red and black leads from the cook-top to the corresponding leads in the junction box.

White wire

 

Green wire

U.L.Listed conduit

FigureA

with yellow

connector

Cable from

 

 

stripes

 

 

cook-top

 

 

Cable from

 

power supply

Ungrounded neutral

Junction box

 

Red wires

Twist-on. connectors

4-wire branch circuit

Refer to Figure B:

Connect the green and yellow striped GROUND wire from the cook-top to the GROUND wire in the junction box (bare or green color wire).

Connect the red and black leads from the cook-top to the corresponding leads in the junction box.

Place a twist-on connector on the end of the NEUTRAL (grey or white) Wire.

Black wires

Rare

or

 

green

wire

 

 

Green wire

U.L, Listed conduit

 

with yellow

Figure B

stripes

connector

 

Cable

from

cook-top

10

Page 10
Image 10
Bosch Appliances NKT 72, NKT 92 Electrical Connections, FigureA, Figure B, Grounded neutral, Ungrounded neutral