SC3100 Circuit Board
JP1 - CPU Reset (Reboot)
This allows system reset or initialization of the Central Processor Unit (CPU). Shorting the two pins on this header and cycling the system power will erase the program from the SC3100, making it operate as if it was a “new, out of the box” unit.
Radio
This header is to connect the interface cable from the internal RA500 Radio Module to the radio adapter board inside the SC3100.
JP-3-SP100 Charger Header
This
Note: To operate the SC3100 without the supplied internal battery, remove the SP100 Battery Charger Board and battery, and place a jumper across the two pins closest to the CPU on Header XX. This requires a stable well- regulated power source for operation without the internal battery.
Battery Cut-Off Relay
This relay disconnects the internal 12VDC battery from the SC3100 circuitry when the external DC power source is removed.
Note: Once the SC3100 is programmed and brought
R42 - TX Dev Adj
This is the adjustment for the Radio Transmitter Modulation Deviation set by Bosch Security Systems at the factory. Do not make field adjustments.
Do not make field adjustments. Field adjustments of the Radio Transmitter Deviation made by unauthorized personnel may violate FCC regulations.
U1 - Microprocessor
This contains the system program the SC3100 needs to operate. This program is downloaded into the microprocessor from the SAFECOM computer via the SAFECOM radio network when the SC3100 is first powered up. The label on the microprocessor specifies the CPU S/N and PID # of this particular SC3100.
U3 - Modem Chip
This is the SC3100 Modem used for converting the Serial Data stream from the SC3100 main board to an audio signal that can be transmitted via the SAFECOM radio network.
2.2System Status LED Indications
The System Status LED lights up to indicate the status of radio communications between the SC3100 and the Central Station SC9000 computer. It also can indicate a low internal battery condition. The System Status LED also functions as a hardware fault indicator.
There are 5 types of System LED indications for various conditions of a properly programmed SC3100 in the field:
•Rapid blinking green: The System LED blinks green continuously at a rate of 5 times per second. After 90 seconds of
•Rapid blinking red: The System LED blinks red continuously at a rate of 5 times per second. After 90 seconds of
•Slow blinking red: The System LED blinks red slowly 5 times, then pauses for one second, then returns to the 5 slow red blinks. This LED indicates that the SC3100 system has shut down because the charge on the SC3100 internal battery is so low that it cannot activate the radio transmitter to send a message.
Communications = Bad, Battery = Bad
The SC3100 will attempt to
| SC3100 Operation and Installation Guide |
|
|
| |