“Dialer ACK”:

SC3100

System Initialization

Note: For older SC3100s, the programming version required the operator to set two parameters, “Dialer ACK” and “Dialer Format” as shown below.

“Dialer ACK”:

0= Short burst 2300 Hz, short burst 1400 Hz, long burst 2300 Hz, long burst 1400Hz. 1= Short burst 2300 Hz, short burst 2300 Hz.

2= Short burst 1400 Hz, short burst 1400 Hz. 3= Long burst 2300 Hz, long burst 2300 Hz. 4= Long burst 1400 Hz, long burst 1400 Hz.

5= DTMF (ADEMCO Contact ID / 4+2 Express / High Speed).

“Dialer Format”:

0= Unknown Dialer Format or any DTMF based format. 4= 3+1 Pulse, double round.

5= 3+1 Pulse with parity.

6= Long burst 2300 Hz, long burst 2300 Hz. 4= Long burst 1400 Hz, long burst 1400 Hz.

5= DTMF (ADEMCO Contact ID / 4+2 Express / High Speed).

“Digital Format”:

Note: For newer SC3100s, please note that the programming for the newest versions required the operator to set only one parameter called "Digital Format” as shown below.

00= Either 2300 Hz or 1400 Hz ACK Tone, Any digital pulse type format.

 

01= Either 2300 Hz or 1400 Hz ACK Tone, Radionics BFSK.

 

02= Either 2300 Hz or 1400 Hz ACK Tone, 0-2 pulse type format.

 

03= Either 2300 Hz or 1400 Hz ACK Tone, 0-2 pulse type format with parity.

 

04= Either 2300 Hz or 1400 Hz ACK Tone, 3+1 pulse type format

 

05= Either 2300 Hz or 1400 Hz ACK Tone, 3+1 pulse type format with parity.

 

06= Either 2300 Hz or 1400 Hz ACK Tone, 4+2 pulse type format

 

07= Either 2300 Hz or 1400 Hz ACK Tone, 4+2 pulse type format with parity.

 

08= Either 2300 Hz or 1400 Hz ACK Tone, FBI Superfast (DTMF)

 

10= 2300 Hz ACK Tone, Any digital pulse type format.

 

11= 2300 Hz ACK Tone, Radionics BFSK.

 

12= 2300 Hz ACK Tone, 0-2 pulse type format.

 

13= 2300 Hz ACK Tone,

0-2 pulse type format with parity.

 

14= 2300 Hz ACK Tone, 3+1 pulse type format

 

15= 2300 Hz ACK Tone,

3+1 pulse type format with parity.

 

16= 2300 Hz ACK Tone, 4+2 pulse type format

 

17= 2300 Hz ACK Tone,

4+2 pulse type format with parity.

 

18= 2300 Hz ACK Tone, FBI Superfast (DTMF)

 

20= 1400 Hz ACK Tone, Any digital pulse type format.

 

21= 1400 Hz ACK Tone, Radionics BFSK.

 

22= 1400 Hz ACK Tone, 0-2 pulse type format.

 

23= 1400 Hz ACK Tone,

0-2 pulse type format with parity.

 

24= 1400 Hz ACK Tone, 3+1 pulse type format

 

25= 1400 Hz ACK Tone,

3+1 pulse type format with parity.

 

26= 1400 Hz ACK Tone, 4+2 pulse type format

 

27= 1400 Hz ACK Tone,

4+2 pulse type format with parity.

 

28= 1400 Hz ACK Tone, FBI Superfast (DTMF)

 

 

 