Bosch High Performance

Installing the Monitor en 33

HD LED Monitors

 

 

 

Example: Typical Alarm Trigger Configuration

In this case, the Dinion camera is used to watch for motion. When the camera detects motion it sends an alarm to the UML monitor. The monitor, then, switches the input to display the video from the Dinion camera and sounds a buzzer.

1.Route the coax cable from the Dinion Video output to the AV1 input of the UML monitor.

2.Configure the following settings for the Dinion camera:

VMD: OSD

Area: 1

Active: On

3.Connect one flying lead to relay output three, on the back of the Dinion camera, and connect the other to relay output four.

4.Connect the other end of the Trigger Relay cable to the Trigger Input connector on the back of the monitor.

5.Plug the monitor into a power socket; then press the Power button.

6.On the monitor, access the Trigger menu: Press the Menu button.

Press the Down arrow button to access the Setting menu. Press the Right arrow button to enter the Setting menu. Press the Down arrow button until Trigger is highlighted; then press the Right arrow button.

7.Make the necessary changes to the Trigger menu so that the settings match the following:

Bosch Security Systems, Inc.

Installation Manual

2013.02 3.0

Page 33
Image 33
Bosch Appliances UML-273-90 installation manual Example Typical Alarm Trigger Configuration, Vmd Osd