VG4 Modular Camera System

Configuring the IP AutoDome en 97

 

 

Deactivating Storage Media

You can deactivate any storage medium from the Managed storage media list. It is then no longer used for recordings.

1.Click a storage medium in the Managed storage media list to select it.

2.Click the Remove button below the list. The storage medium is deactivated and removed from the list.

10.40Advanced Mode: Recording Profiles

You can define up to ten different recording profiles. You will then use these recording profiles in the recording scheduler, where they are linked with the individual days and times (see Section 10.42 Advanced Mode: Recording Scheduler, page 97).

NOTICE!

You can change or add to the recording profile description on the tabs on the Recording Scheduler page (see Section Time periods, page 98).

1.Click one of the tabs to edit the corresponding profile.

2.If necessary, click the Default button to return all settings to their default values.

3.Click the Copy Settings button if you want to copy the currently visible settings to other profiles. A new window will open and you can select the profiles in which you want to copy the settings.

4.For each profile, click the Set button to save the settings in the unit.

Stream profile settings

You can select the profile setting that is to be used for each data stream in the event of recordings. This selection is independent of the selection for live data stream transmission (see Section 10.17 Advanced Mode: Encoder Streams, page 80).

The properties of the profiles are defined on the Encoder Profile page (see Section 10.16 Advanced Mode: Encoder Profile, page 78).

Recording includes

You can specify whether, in addition to video data, audio data and metadata (for example alarms, VCA data and serial data) should also be recorded. Including metadata could make subsequent searches of recordings easier but it requires additional memory capacity.

CAUTION!

Without metadata, it is not possible to include video content analysis in recordings.

Standard recording

Here you can select the mode for standard recordings.

If you select Continuous, the recording proceeds continuously. If the maximum memory capacity is reached, older recordings will automatically be overwritten. If you select the Pre- alarm option, recording will only take place in the pre-alarm time, during the alarm and during the set post-alarm time.

If you select Off, no automatic recording takes place.

CAUTION!

You can specify limitations for overwriting older recordings in Continuous mode by configuring the retention time (see Section 10.41 Advanced Mode: Retention Time, page 97).

Bosch Security Systems, Inc.

User’s Manual

F.01U.133.268 6.0 2010.03

Page 98
Image 98
Bosch Appliances VG4-500I 10.40Advanced Mode Recording Profiles, Deactivating Storage Media, Stream profile settings

VG4-500I, VG4-200, VG4-300 specifications

Bosch Appliances is renowned for its commitment to quality and innovation, and their VG4 series of ventilation hoods is no exception. The VG4-300, VG4-200, and VG4-500I models are designed to cater to various kitchen needs, providing effective air filtration while maintaining aesthetic appeal.

The VG4-300 model is characterized by its sleek design and robust performance. It features a powerful motor that delivers efficient ventilation, removing smoke, odors, and grease from your kitchen swiftly. One of the standout features is its three-speed fan system, which allows users to select the appropriate level of airflow based on cooking intensity. Additionally, the grease filter is dishwasher-safe, ensuring easy maintenance and longevity.

In contrast, the VG4-200 model is perfect for those seeking a compact yet powerful solution. Designed for smaller kitchens, it doesn’t compromise on performance. This model also offers a three-speed fan, providing sufficient airflow for everyday cooking activities. The LED lighting integrated into the design enhances visibility on your cooktop while adding a modern touch to your kitchen. With a focus on energy efficiency, the VG4-200 operates quietly, allowing for a pleasant cooking experience without distraction.

The VG4-500I model is a standout in the series, designed for larger, more demanding kitchens. With increased airflow capacity, it can handle vigorous cooking styles with ease. It also boasts an advanced filtration system that captures more airborne particles, enhancing indoor air quality. The model features a touch control panel for ease of use, giving users the ability to adjust settings seamlessly. Like its counterparts, the VG4-500I includes LED lighting and dishwasher-safe filters, making maintenance straightforward.

All three models in the VG4 series exemplify Bosch's dedication to advanced technologies. Noise reduction features ensure that the ventilation system operates quietly, allowing conversations in the kitchen without disturbance. Furthermore, the stylish and modern finishes of each model enhance kitchen aesthetics, making them suitable for any decor.

In summary, Bosch Appliances’ VG4-300, VG4-200, and VG4-500I ventilation hoods offer a range of features tailored to meet different culinary needs. From effective air filtration and energy-efficient operation to user-friendly controls and elegant designs, these models are crafted to elevate the cooking experience while ensuring a fresh and clean kitchen environment.