WFL 2060 Service Tips
WFL 2060 Service Tips --
-- Resistance
Resistance
Measurements from Control Module (1)
Measurements from Control Module (1)
69
1st Edition/Revision 5 (1/20/04)
TopTop
1
1
Disconnect & measure white 5-pin connector (with 3
black wires) to measure dual cold water valve. Valve
should read (pin 1 is at bottom):
Main wash (pins 1-3): 2.7 - 4.5 k
Prewash (pins 1-5): 2.7 - 4.5 k
Disconnect & measure blue 2-
pin connector (with blue
wires) to measure drain pump.
Pump should read ~ 80 - 94
Disconnect & measure tan 3-pin connector (with 2
black wires) to measure NTC. NTC should read:
20ºC (68ºF): 5.4 - 6.5 k
30ºC (86ºF): 3.5 - 4.3 k
40ºC (104ºF): 2.3 - 2.9 k
Disconnect & measure tan 3-pin
connector (with 2 black wires) to
measure hot water valve. Valve
should read 2.7 - 4.5 k.
WARNING! Unplug washer before making any resistance measurements.