WFR 2460 Service Tips
WFR 2460 Service Tips --
-- Resistance Resistance Measurements from Control Module (2)Measurements from Control Module (2)
72
1st Edition/Revision 5 (1/20/04)

WARNING! Unplug washer before

making any resistance measurements.

1
1
Disconnect & measure white 5-pin
connector (with 3 black wires) to
measure dual cold water valve. Valve
should read (pin 1 is at right):
Main wash (pins 1-3): 2.7 - 4.5 k
Prewash (pins 1-5): 2.7 - 4.5 k
1
1
Disconnect & measure white 2-pin connector (with
black wires) to measure hot water valve. Valve
should read 2.7 - 4.5 k.
Disconnect & measure 2 connectors to measure heater.
Measure between pin 1 (1-pin connector at bottom of group of 3
connectors at left of module) and pin 2 (2nd pin from right) of
pressure switch connector. Heater should read 23.2 - 29.4 ..
Pink
connector
with pink
wires
Connector
with pink
wire
HINT If necessary to access connectors,
carefully pry control module tabs and
remove module from fascia panel.