WFR 2460 Service Tips
WFR 2460 Service Tips --
-- Resistance
Resistance
Measurements from Control Module (1)
Measurements from Control Module (1)
71
1st Edition/Revision 5 (1/20/04)
1
1
1
11
1
Disconnect & measure white 3-pin
connector (with blue wires) to
measure door latch motor. Measure
between pins 1-2 (pin 1 at far left).
Motor should read ~ 211 - 259 .
Disconnect & measure white 2-pin
connector (with black wires) to
measure NTC. NTC should read:
20ºC (68ºF): 5.4 - 6.5 k
30ºC (86ºF): 3.5 - 4.3 k
40ºC (104ºF): 2.3 - 2.9 k
Disconnect & measure blue 2-pin
connector (with blue wires) to
measure drain pump. Pump should
read ~ 80 - 94 .
Disconnect & measure white 6-pin connector (with blue wires) to
measure drum drive motor. Motor should read (pin 1 is at far right):
Pins 1-2: 14 - 35
Pins 3-4: 1.5 - 10
Pins 5-6: 0.7 - 2.1
WARNING!
Unplug washer
before making
any resistance
measurements.