Bose IMPORTANT Before you calibrate Auto Volume, Auto Volume setup procedure, Sense E4 System

Models: E4

1 33
Download 33 pages 3.85 Kb
Page 24
Image 24
IMPORTANT: Before you calibrate

6.0 E4 System Setup

IMPORTANT: Before you calibrate

Auto Volume

Make sure that the system hardware installation is complete and that all components (sense microphones, speakers, and Auto Volume user interfaces) are properly connected. Remem- ber that speakers must be directly wired to the ZONE OUT connectors on the E4 rear panel.

Sense E4 System

 

 

 

ZONE 1

 

 

 

 

Mic

 

 

 

 

 

 

 

ZONE OUT 1

 

 

 

 

 

Speaker

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WALL PLATE

 

 

 

 

 

Auto Volume

 

 

 

 

 

 

 

 

 

 

 

 

 

CONNECTION 1

 

 

 

 

 

user interface

 

 

 

 

 

 

 

 

 

 

 

Make sure that you have selected the correct speaker model in the ZONE setup pane.

Make sure that the output gain is set so that the source can be heard without dropping out.

Check that sources have been assigned to zones.

Programmer’s Note: If a source is routed to multiple zones, you need to perform Auto Volume calibration on that source only once. After calibration, the source is “locked” (no adjustments to the source will be allowed) until all zones using that source have been reset.

Check the EQ pane and make any final adjustments.

DO NOT USE AUTOTRANSFORMERS: Speakers must be directly wired to the ZONE OUT connector of the E4 hardware. DO NOT use an autotransformer on the speaker line to adjust the speaker volume. If you lower the volume using an autotransformer, the E4 system will raise the volume. Likewise, if you raise the volume using an autotransformer, the E4 sys- tem will lower the volume.

 

 

 

 

 

Volume

 

 

 

ZONE 1

Sense E4 System

Adjustment

 

 

 

 

 

 

 

 

 

 

 

 

 

Mic

 

 

 

 

 

 

 

ZONE OUT 1

 

 

 

 

 

Speaker

 

 

 

 

 

 

 

 

 

 

 

 

 

WALL PLATE

 

 

 

 

 

Auto Volume

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONNECTION 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

user interface

 

 

 

 

 

 

 

 

 

 

Auto Volume setup procedure

Programmer’s Note: While the Auto Volume calibra- tion is running,

• DO NOT use the paging microphone.

Wait for the Auto Volume calibration to finish before adjusting other system functions.

DO NOT disconnect the RS-232 cable from the E4 unit.

1.Click Sense E4 System button for the zone you want to calibrate.

2.Click More to display the Auto Volume Tracking settings.

3.Select Auto Volume Tracking settings for the type of system used in this zone. See “Auto Volume Tracking settings” on page 58.

4.Click Set Up to start the Auto Volume Setup process. The initial Auto Volume Setup dialog appears in the window.