Troubleshooting

Regarding the indicator lamps (continued)

POWER

LAMP

TEMP

Description

 

indicator

indicator

indicator

ENGLISH

 

 

 

 

 

Blinking

 

 

Please turn the power off, and allow the unit to cool

 

 

 

The cooling fan is not operating.

 

In Red

Turned

 

down at least 20 minutes. After the projector has

 

Blinking

sufficiently cooled down, please make confirmation

 

or

 

off

In Red

that no foreign matter has become caught in the fan,

 

Lighting

 

 

 

etc., and then turn the power on again.

 

In Red

 

 

 

 

 

If the same indication is displayed after the treatment,

 

 

 

 

 

 

 

 

please contact your dealer or service company.

 

 

 

 

There is a possibility that the interior portion

 

 

 

 

has become heated.

 

 

 

 

Please turn the power off, and allow the unit to cool

 

Blinking

 

 

down at least 20 minutes. After the projector has

 

 

 

sufficiently cooled down, please make confirmation of

 

In Red

 

 

 

Turned

Lighting

the following items, and then turn the power on again.

 

or

 

off

In Red

• Is there blockage of the air passage aperture?

 

Lighting

 

 

 

• Is the air filter dirty?

 

In Red

 

 

 

 

 

• Does the peripheral temperature exceed 35°C?

 

 

 

 

 

 

 

 

If the same indication is displayed after the treatment,

 

 

 

 

please set the HIGH at the FAN SPEED of the item

 

 

 

 

SERVICE of the OPTION menu.

 

 

 

 

There is a possibility that the interior portion

 

Lighting

Alternative

has become overcooled.

 

Please use the unit within the usage temperature

 

In Green

blinking in Red

 

parameters (5°C to 35°C). After the treatment, resent

 

 

 

 

 

 

 

 

the power to ON.

 

 

 

 

It is time to clean the air filter.

 

Lighting

Simultaneous

Please immediately turn the power OFF, and clean

 

or change the air filter by referring to the section “Air

 

In Green

blinking in Red

Filter”. After cleaning or changed the air filter, please

 

 

 

 

be sure to reset the filter timer. After the treatment,

 

 

 

 

resent the power to ON.

 

NOTE • When the interior portion has become overheated, for safety purposes, the power source is automatically turned off, and the indicator lamps may also be turned off. In such a case, press the “” (OFF) side of the power switch, and wait at least 45 minutes. After the projector has sufficiently cooled down, please make confirmation of the attachment state of the lamp and lamp cover, and then turn the power on again.

45

Page 45
Image 45
BOXLIGHT CP-324i user manual Regarding the indicator lamps, Cooling fan is not operating, Has become overcooled