BRADFORD WHITE CORP.

 

 

9Fuel

N = Natural Gas P = Propane

10Altitude

A = 0–10,000 feet

11Location

C = Indoor and Outdoor

12Firing Mode K = Two-stage

13Revision

1 = First version of design

14Heat Exchanger

B = Glass-lined cast iron / copper / bronze trim

(std. on BMT2V)

C = Glass-lined cast iron / copper

(std. on BMT2H)

K = Bronze / copper

N = Glass-lined cast iron / cupro-nickel

(n/a on water heaters)

P = Glass-lined cast iron / cu-nickel / bronze trim S = Bronze / cupro-nickel

15Option Code

X = Standard unit

J = CSD-1, FM, IRI, IL

16Pump Options

H = Pump mounted BMT2V, hard water pump N = Pump mounted (any), normal water pump

1.3 Warranty

Bradford White’s appliances are covered by a limited warranty. Owners should submit online warranty registration at www.branfordwhite.com.

All warranty claims must be made to an authorized Bradford White representative or directly to Customer Service. Claims must include the serial number and model (this information can be found on the rating plate), installation date, and name of the installer. Shipping costs are not included in the warranty coverage.

Some accessory items are shipped in separate packages. Verify receipt of all packages listed on the packing slip. Inspect everything for damage immediately upon delivery, and advise the carrier of any shortages or damage. Any such claims should be filed with the carrier. The carrier, not the shipper, is responsible for shortages and damage to the shipment whether visible or concealed.

1.4Dimensions

See Figures 1 and 2.

1.5Locating the Appliance

The appliance should be located to provide clearances on all sides for maintenance and inspection. It should not be located in an area where leakage of any connections will result in damage to the area adjacent to

the appliance or to lower floors of the structure. When such a location is not available, it is

recommended that a suitable drain pan, adequately drained, be installed under the appliance.

The appliance is design certified by CSA- International for installation on combustible flooring; in basements; in closets, utility rooms or alcoves. Brute

Deluxe Boilers or Water Heaters must never be installed on carpeting. The location for the appliance should be chosen with regard to the vent pipe lengths and external plumbing. The unit shall be installed such that the gas ignition system components are protected from water (dripping, spraying, rain, etc.) during operation and service (circulator replacement, control replacement, etc.). When vented vertically, the Brute Deluxe must be located as close as practical to a chimney or outside wall. If the vent terminal and/or combustion air terminal terminate through a wall, and there is potential for snow accumulation in the local area, both terminals should be installed at an appropriate level above grade.

The dimensions and requirements that are shown in Table 1 should be met when choosing the locations for the appliance.

1.6Locating Pump-Mounted Water Heater with Respect to Storage Tank(s)

For best results, a pump-mounted Brute Deluxe water heater should be located within 15 feet (4.6m) of the storage tank(s). The pump is sized for 30 feet (9.1m) of piping.

If the appliance must be installed with longer piping runs, then larger diameter pipe or tubing shall be used. Consult the factory for assistance.

1.7Locating Pump-Mounted Boiler with Respect to Return/Supply Header

For the best results, a pump-mounted Brute Deluxe

 

REQUIRED

 

RECOMMENDED

APPLIANCE

CLEARANCE FROM

 

SERVICE ACCESS

SURFACE

COMBUSTIBLE MATERIAL

 

CLEARANCE

 

inches

cm

 

inches

cm

 

 

 

 

 

 

Left Side

1

2.5

24

61

Right Side

1

2.5

24

61

Top

1

2.5

12

30

Back

1

2.5

**12**

30**

Front

1

2.5

36

91

Vertical

 

 

 

 

 

(Category 1)

6*

15.2*

 

 

 

Vent

 

 

 

 

 

Horizontal

per UL1738 venting

 

 

 

(Category 3)

system supplier’s

 

 

 

Vent

instructions

 

 

 

*1" (2.5cm) when b-vent is used.

**When vent and/or combustion air connects to the back, recommended clearance is 36" (91cm).

Table 1. Clearances.

Page 4
Image 4
Bradford-White Corp BMT2H, BMT2V warranty Warranty, Dimensions, Locating the Appliance, Clearances

BMT2H, BMT2V, Hydronic Boiler, Water Volume Heater specifications

Bradford-White Corporation, a leader in the water heating and hydronic heating industries, offers an impressive range of products designed to meet diverse residential and commercial needs. Among their notable innovations are the BMT2V and BMT2H series hydronic boilers and water volume heaters, which combine state-of-the-art technology with user-friendly features.

The BMT2V and BMT2H models are designed to deliver high-efficiency heating solutions for various applications. One of the key features of these boilers is their superior thermal efficiency, which reduces fuel consumption while ensuring optimal output. With a range of BTU inputs suitable for different heating needs, these boilers can provide efficient heating for residential, commercial, and industrial applications.

Both the BMT2V and BMT2H units are built with advanced combustion technology, allowing for cleaner and more efficient burning of fuel. This not only contributes to lower emissions but also ensures that the boilers operate quietly and reliably. The integrated draft inducer further enhances the efficiency of the combustion process by optimizing airflow, leading to improved overall performance.

Another standout characteristic of these models is their robust construction. Made with high-quality materials, the BMT2V and BMT2H boilers are designed to endure harsh operational conditions while providing long-lasting performance. The tanks are lined with corrosion-resistant coatings, which significantly extend the lifespan of the unit and reduce maintenance requirements.

Both models are also equipped with smart control systems that enable precise temperature regulation and easy monitoring of system performance. These controls allow users to adjust settings remotely or via integrated digital interfaces, further enhancing user convenience. Additionally, the integration of safety features, such as pressure relief valves and automated shut-off systems, ensures safe operation.

The BMT2 series also emphasizes ease of installation and maintenance. Compact designs and flexible venting options allow for versatile installation in various environments. Serviceability is streamlined through easily accessible components, ensuring that technicians can perform maintenance tasks efficiently.

In summary, Bradford-White's BMT2V and BMT2H hydronic boilers and water volume heaters embody efficiency, durability, and advanced technology. With their focus on sustainability and high performance, these models are ideal choices for anyone looking to invest in reliable heating solutions.