Bradley Smoker S53-309, S53-308, S53-307, 232-007 For the sensor and solenoid cables pages 4

Models: S53-307 232-007 S53-309 S53-306 S53-308

1 8
Download 8 pages 51.7 Kb
Page 8
Image 8

Aerada 1000 Series Gooseneck Faucet

Installation Instructions

Troubleshooting continued . . .

Problem

Check

Possible Solution

Faucet works in reverse.

Solenoid wiring on DIN connector

Replace solenoid.

 

(no beeps).

 

 

 

 

Faucet turns off too soon.

Faucet operating mode (no beeps) or

Change mode or range setting using DIPswitch (page 6).

 

faucet range setting.

 

 

 

 

Faucet stays on longer than

Dirty solenoid valve (no beeps).

Clean internal parts or replace solenoid valve.

normal.

 

 

Clogged spout outlet.

Clean outlet.

 

 

 

 

 

Faucet in wrong mode (no beeps).

Change mode setting using DIPswitch (page 6).

 

 

 

Faucet stopped working.

Mounting of electronics cover (no beeps).

Electronics cover must be mounted to allow for drip loops

 

 

for the sensor and solenoid cables (pages 4 & 5).

 

 

 

 

Sensor cable connector.

Clean connector.

 

 

 

 

No clicking sound from solenoid during

Reset electronics using reset button (page 6).

 

hand presence (no beeps).

 

 

 

 

 

Solenoid valve strainer.

Clogged strainer. Clean if necessary.

 

 

 

 

Check if faucet outlet is clogged

Clean faucet outlet.

 

(no beeps).

 

 

 

 

 

Battery voltage (battery operated only).

Replace batteries if below 4.2 volts.

 

 

 

 

Incorrect range setting for spout type and

Change range setting using DIPswitch (page 6).

 

sink used (no beeps).

 

 

 

 

 

 

 

8

9/23/04

Bradley Corporation • 215-1559 Rev. A; EN 04-216A

Page 8
Image 8
Bradley Smoker S53-309, S53-308, S53-307, 232-007, S53-306 installation instructions For the sensor and solenoid cables pages 4