Installation InstructionsAerada 1000 Series Gooseneck Faucet
Troubleshooting
Whenever new batteries are installed, AC power is applied, |
| The following chart provides details concerning the number | ||
or a manual reset button is pressed, the LED on the |
| of beeps and possible errors associated with them . | ||
electronics cover will blink and an audible indicator chirps |
| 1 | Beep: | Indicates low battery. |
twice per second whenever hand presence is detected. |
| |||
After 8 minutes, the LED and buzzer function stops. |
| 2 | Beeps: | Calibration out of range (environment too |
|
| |||
If an error occurs, the LED will blink and the buzzer will |
|
|
| reflective). |
sound every 30 seconds to assist in diagnosing the |
| 3 | Beeps: | Room infrared level out of range; too much |
problem. When corrective action is taken the LED and |
| |||
|
|
| sunlight, heat lamp present, etc. | |
buzzer will stop. |
|
|
| |
|
|
|
| |
|
| 4 | Beeps: | Solenoid short circuit. |
| ||||
|
| 5 | Beeps: | Solenoid unplugged or loose/broken solenoid |
|
|
|
| connection. |
|
| Refer to Troubleshooting Chart below and on page 8 for | ||
|
| further troubleshooting information. | ||
|
|
|
|
|
Problem | Check | Possible Solution |
|
|
|
Water runs continuously. | Debris in solenoid (no beeps). | Disassemble solenoid and inspect/clean parts. |
|
|
|
| Water pressure too high (no beeps). | Reduce pressure to under 80 PSI. |
|
|
|
Faucet turns on by itself | Incorrect range setting for spout type and | Change range setting using DIPswitch (page 6). |
(ghosting). | sink used (2 beeps). |
|
|
|
|
No water flow. | Water not turned on (no beeps). | Turn on water supply. |
|
|
|
| Solenoid cable not connected to | Check connection. |
| electronics cover (5 beeps). |
|
|
|
|
| Solenoid short circuit (4 beeps). | Replace electronics cover. |
|
|
|
| Sensor cable not connected to electronics | Check connection. |
| cover (no beeps). |
|
|
|
|
| Inoperative sensor (no beeps). | Inspect collar wiring for signs of damage or corrosion. |
|
| Replace if necessary. |
|
|
|
| Inoperative electronics cover assembly | Replace cover assembly. |
| (no beeps). |
|
|
|
|
| Water pressure too high (no beeps). | Reduce pressure to under 80 PSI. |
|
|
|
| Low battery voltage (DC only) (1 beep). | Replace batteries (DC only). |
|
|
|
| 6VDC transformer not properly connected | Use correctly sized terminal clips (page 4). |
| to partition assembly (no beeps). |
|
|
|
|
| Wiring of multiple unit 6VDC transformer | Faucets must be wired in parallel from transformer |
| (no beeps). | (transformer to each individual unit), not connected in |
|
| a series. |
|
|
|
Range too short or too long. | Interference during automatic calibration | Remove interference; reset electronics using reset |
| (no beeps). | button (page 6). Allow 30 seconds for faucet to |
|
| automatically |
|
|
|
| Incorrect range setting for type of spout | Change range setting using DIPswitch (page 6). |
| and sink used. |
|
|
|
|
| Lighting environment affecting sensor | Change range setting using DIPswitch (page 6). |
| (3 beeps). |
|
|
|
|