Braun 6 manual Maintenance and Lubrication

Models: 6

1 45
Download 45 pages 8.72 Kb
Page 40
Image 40

Maintenance and Lubrication

Maintenance is necessary to ensure safe and trouble-free lift operation. General preventive maintenance consisting of inspections of your lift system and cleaning the lift should be a part of your routine.

The L915 has been designed with many self-lubricating compo- nents. Lubricate the pivot points specified on page 39 approxi- mately every four weeks (or 100 cycles) with a light penetrating type oil (30 weight or equivalent). Severe conditions (weather, environment, heavy usage, etc.) may require more frequent lubrication.

Preventive maintenance visual inspections and lubrication procedures do not take the place

of the procedures specified in the Maintenance and Lubrication Schedule provided in the appli- cable lift installation and service manual. The procedures outlined in the Maintenance and Lubrica- tion Schedule must be per- formed at the recommended scheduled intervals by an authorized Braun Corporation service representative who has attended and been certified by The Braun Corporation Sales and Service School.

If the scheduled maintenance and lubrication procedures are not being performed, or if there is any sign of lift damage, wear, abnor- mal condition or improper opera- tion, discontinue lift use imme- diately. Contact your sales representative or call The Braun

Corporation at 1-800-THE LIFT. One of our national Product Support representatives will direct you to an authorized service technician who will inspect your lift.

WARNING

Maintenance and lubrication proce- dures must be per- formed by authorized service personnel as specified in the applicable installa- tion/service manual. Failure to do so may result in serious bodily injury and/or property damage.

Page 38

Page 40
Image 40
Braun 6 manual Maintenance and Lubrication