Decals and Antiskid

Decals

32410

LCD Lift Codes

25580

Listed below are codes that the lift controller outputs during lift operation. The codes will be displayed on an LCD screen located on the lift control board inside the pump module.

Non-Flashing Numbers

01 – Platform stowed

02 – Platform unfolding

03 – Platform unfolding paused

04 – Platform at floor level

05 – Platform beginning to lower

06 – Platform lowering (threshold cannot be occupied from this point down)

07 – Outer barrier moving to horizontal position

08 – Platform at ground level

09 – Outer barrier moving to vertical position

10 – Platform raising

11 – Platform raising paused at floor

12 – Platform folding (limited pressure)

13 – Platform folding (full pressure)

14 – Timed fold (cinching lift tite) or (anti-rattle state)

15 – Platform folding stopped

16 – Paused fold

17 – Platform between ground and 3" above ground

18 – Platform above 3"

19 – Outer barrier moving to horizontal postion

20 – The doors are not fully opened (only applicable when door operators are installed)

21 – The doors are opening (only applicable when door operators are installed)

22 – The doors are closing (only applicable when door operators are installed)

28 – Illegal function/not defined

29 – Interlock fault not recognized (or has been cleared but a motion button is still pressed)

30 – Platform location unknown

31 – Platform location transition state; attempting to locate position

35 – Two or more motion buttons are being pressed

36 – The retention belt cannot be buckled while trying to fold or unfold

37 – Motion button being pressed is not a valid motion

50 – Outer barrier is not up above inboard barrier locked position

51 – Threshold is occupied when platform is

1" or more below floor level

52 – Inner rollstop is not up and locked below inner rollstop locked position

53 – Inner rollstop occupied sensor is not activated between floor and inner rollstop up position

54 – Outer barrier is occupied before it is up 55 – Outer barrier is not latched when above the inner rollstop locked position

(Millennium only)

56 – Outer barrier is not up and latched and bridge switch did not deactivate

57 – Outer barrier is not up and latched and ground detect switch did not deactivate (Century and Vista only)

58 – Outer barrier is not up and latched and the platform is 3" above the ground

59 – Outer barrier is not up after pausing platform travel

60 – The kickout gas springs are worn, replace before using

75 – Low voltage detected; must turn off power switch to reset LCD

77 – Vehicle secure interlock has not been activated

90 – Position will be set if you keep holding the button until it beeps

91 – Position is out of a predetermined acceptable range of floor position

92 – Bridge switch is not made, needs adjusting

93 – Inner rollstop occupied switch is not made,

position needs to be moved or switch should be adjusted

94 – Outer barrier is not made, fix and try again 95 – Outer barrier latch is not made (check for

jumper on Century and Vista lifts, check latch on Millennium lifts)

99 – Controller program is not valid; replace controller

Flashing Numbers

Flashing 65 – Unfold button is pressed Flashing 66 – Fold button is pressed Flashing 67 – Down button is pressed Flashing 68 – Up button is pressed Flashing 69 – Bridge switch is activated Flashing 70 – Outer barrier latch switch is

activated

Flashing 71 – Ground detect switch is activated Flashing 72 – Outer barrier up switch is activated Flashing 73 – Inner rollstop up switch is activated Flashing 74 – Inner rollstop occupied switch is

activated

Flashing 76 – Outboard barrier occupied switch is activated

Flashing 78 – Threshold tape switch “A” is activated

Flashing 79 – Threshold tape switch “B” is activated

Flashing 80 – Position set button is pressed Flashing 81 – Single function UP / FOLD /

CLOSE button is pressed Flashing 82 – Single function OPEN / UNFOLD /

DOWN button is pressed Flashing 87 – CLOSE button is pressed Flashing 88 – OPEN button is pressed Flashing 89 – Door full open switch is activated

(or jumper is installed on control board)

32201

PLATFORM FOLD

RELIEF VALVE

ADJUSTMENT

Platform Fold

Relief Valve:

See service

manual for

adjustment

procedure.

30787

CAUTION

Improper handling

and/or servicing

procedures may

result in

electrostatic

discharge (ESD)!

ESD may result in

electronic module

damage.

25580

18229

MADE IN

AMERICA

Quality inspected

 

By:



18229

25652

32410

32201

30787

25652

Page 41

Page 43
Image 43
Braun NL955 manual 30787