Maintenance and Lubrication Schedule

 

 

Inspect torque tube cams for securement, wear or

Resecure, replace or correct as needed.

 

 

damage

 

 

1500

 

Inspect housing cam brackets for securement,

Resecure, replace or correct as needed.

Cycles

 

wear or damage

 

 

 

 

Inspect cylinder(s), hoses, fittings and hydraulic

Tighten, repair or replace if needed.

 

 

connections for wear, damage or leaks

 

 

 

 

Inspect power cable

Resecure, repair or replace if needed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Perform all procedures listed in previous section also

 

 

 

 

 

 

 

 

 

Hydraulic Fluid (Pump) - Check level. Note: Fluid

Use 5606 aviation fluid only (part 87010R-MILL).

 

 

should be changed if there is visible contamination.

Check fluid level with platform lowered fully. Fill

 

 

Inspect the hydraulic system (cylinder, hoses, fit-

to within 1-1/2" of the bottom of the fill tube (neck).

 

 

tings, seals, etc.) for leaks if fluid level is low.

 

 

4500

 

Inspect lifting arm bushings and pivot pins for vis-

Replace if needed.

Cycles

 

 

ible wear or damage

 

 

 

 

 

 

 

 

Inspect outer barrier pivot pin mounting bolts (2)

Tighten or replace if needed

 

 

Mounting

Check to see that the lift is securely anchored to

 

 

 

the vehicle and there are no loose bolts, broken

 

 

 

welds, or stress fractures.

 

 

 

 

 