NOTICE

Improper treatment of generator can damage it and shorten its life.

DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.

DO NOT insert any objects through cooling slots.

Use a soft bristle brush to loosen caked on dirt or oil.

Use a vacuum cleaner to pick up loose dirt and debris.

Fuel Valve Maintenance

The fuel valve is equipped with a fuel sediment cup, screen, retaining ring and o-ring that need to be cleaned every 100 hours or once a year (whichever occurs first).

1.Move fuel valve to “Off” position.

2.Remove sediment cup (A) from fuel valve. Remove o-ring (B), retaining ring (C) and screen (D) from fuel valve.

D

C

B

A

3.Wash sediment cup, o-ring, retaining ring, and screen in a nonflammable solvent. Dry them thoroughly.

4.Place screen, retaining ring, and o-ring into fuel valve. Install sediment cup and tighten securely.

5.Move fuel valve to “On” position, and check for leaks. Replace o-ring if there is any leakage.

Engine Maintenance

WARNING

Unintentional sparking can result in fire or electric shock.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR

Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

WHEN TESTING FOR ENGINE SPARK

Use approved spark plug tester.

DO NOT check for spark with spark plug removed.

Oil

Oil Recommendations

We recommend the use of Briggs & Stratton Warranty Certified oils for best performance. Other high-quality detergent oils are acceptable if classified for service SF, SG, SH, SJ or higher. DO NOT use special additives.

Outdoor temperatures determine the proper oil viscosity for the engine. Use the chart to select the best viscosity for the outdoor temperature range expected.

* Below 40°F (4°C) the use of SAE 30 will result in hard starting.

**Above 80°F (27°C) the use of 10W30 may cause increased oil consumption. Check oil level more frequently.

NOTE: Synthetic oil meeting ILSAC GF-2, API

certification mark and API service symbol with

“SJ/CF ENERGY CONSERVING” or higher, is an

acceptable oil at all temperatures. Use of synthetic oil does not alter required oil change intervals.

Checking Oil Level

Oil level should be checked prior to each use or at least every 5 hours of operation. Keep oil level maintained.

1.Make sure generator is on a level surface.

2.Clean area around oil fill and remove oil fill cap.

3.Verify oil is at the point of overflowing at oil fill opening.

4.Replace and tighten oil fill cap.

Adding Engine Oil

1.Make sure generator is on a level surface.

2.Check oil level as described in Checking Oil Level.

3.If needed, slowly pour oil into oil fill opening to the point of overflowing at oil fill.

4.Replace and tighten oil fill cap.

16

BRIGGSandSTRATTON.COM

Page 16
Image 16