SPECIFICATIONS / MAINTENANCE

PRODUCT SPECIFICATIONS

AC Frequency:

. . . . . . . . . . . . . . . . . . 60Hz

Cut-In Pressure Setting:

. . . . . . . . 80 psi (5.6 bars)

Rated AC Voltage:

. . . . . 120 Volts, single phase

Cut/Out Pressure Setting:

. . . . . . . 125 PSI (8.7 bars)

Running Horsepower:

. . . . . . . . . . . . . . . . . 1.2 HP

Tank capacity:

. . . . . . . 6 Gallons (22.5 L)

Pump Type:

Oil Lubricated Direct Drive

Tank Style:

. . . . . Flat, single (Pancake)

Lubricant:

. . . . . . SAE 5W50 Synthetic

Recommended Air Hose Size: . . . .

. . . . . 3/8 inch ID (14mm)

Oil Capacity:

. . . . . . . . 7.168 oz. (200ml)

Air Fittings:

. . . . . . . . . . 1/4 inch NPT

Air Delivery:

 

Quick Connect Fitting Type:

. . . . . . . . . . . . . . . . . . . I/M

At 40 psi

. . . . . . . . . . . . . . . . 4.9 CFM

Operating Temperature Range: . . .

32° to 95°F (0° to + 35°C)

At 90 psi

. . . . . . . . . . . . . . . . 3.6 CFM

Shipping Weight:

. . . . . . . . . 60lbs. (27.3 Kg)

MAINTENANCE

To ensure efficient operation and longer life of the air compressor, prepare and follow a routine maintenance schedule.The routine described in this section is intended for an air compressor used under normal daily working conditions. If necessary, modify the schedule to suit the conditions under which you use your compressor. Modifications will depend upon hours of operation and

working environment. Operating air compressors in extremely dirty or hostile environments will require more frequent maintenance checks.

NOTE: See FEATURES AND CONTROLS and OPERATION for control locations.

Follow the hourly or calendar intervals, whichever occurs first:

Maintenance

 

 

 

 

 

Service Dates

Schedule

 

 

Service Intervals

 

Fill in as you complete

 

 

 

 

 

 

regular service

 

 

 

 

 

 

Maintenance Task

Daily

Weekly

Every 50 Hours

Every 100 Hours

 

 

 

 

 

or Yearly

 

or Yearly

 

 

Inspect Safety Valve

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inspect Fittings/Valves

X

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inspect Oil Level

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Clean Unit

 

X

 

 

 

 

 

 

 

 

 

 

 

 

 

Inspect and Clean Air

 

 

X

 

 

 

 

Filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inspect Pump Oil

 

 

 

 

X*

 

 

 

 

 

 

 

 

 

 

Inspect Intake and

 

 

 

 

X**

 

 

Exhaust Valves

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inspect Safety Labels

 

 

 

 

X***

 

 

 

 

 

 

 

 

 

 

*Change oil after first 100 hours of operation, then every 300 hours thereafter

**Return unit to approved repair center annual for inspection and service

***Inspect annually, replace as necessary

11