OPERATING THE

OPERATION

8000W Portable Generator

PowerBOSS™

 

 

 

OPERATING THE

GENERATOR

CAUTION

Exceeding generator’s wattage/amperage capacity can damage generator and/or electrical devices connected to it.

See “Don’t Overload Generator”.

Start generator and let engine stabilize before connecting electrical loads.

Connect electrical loads in OFF position, then turn ON for operation.

Turn electrical loads OFF and disconnect from generator before stopping generator.

IMPORTANT: Always unplug the battery float charger before starting the generator.

Starting the Engine

Disconnect all electrical loads from the generator. Use the following start instructions:

1.Make sure unit is on a level surface.

IMPORTANT: Failure to start and operate unit on a level surface will cause the unit not to start or shut down during operation.

2.Turn the fuel valve to the “On” position (Figure 5).The fuel valve handle should be vertical (pointing toward the ground) for fuel to flow.

Figure 5 — Fuel Valve

Fuel Valve is shown in “On” position

3.Set Run/Stop switch to “Run” position (Figure 6).

Figure 6 — Run/Stop Switch

4.Follow start instructions given in engine owner’s manual. Push and hold the Ignition switch in start position (Figure 7) until generator starts.To prolong the life of starter components, DO NOT hold Ignition switch in start position for more than 15 seconds, and pause for at least 1 minute between starting atempts.

Figure 7 — Ignition Switch

NOTE: If engine starts but fails to run, or if unit shuts down during operation, make sure unit is on a level surface and check for proper oil level in crankcase.This unit may be equipped with a low oil protection device. See engine manual.

Starting the Engine WARNING

Running engines produce heat.Temperature of muffler and nearby areas can reach or exceed 150°F (65°C).

Severe burns can occur on contact.

Combustible debris, such as leaves, grass, brush, ect. can catch fire.

DO NOT touch hot surfaces.

Allow equipment to cool before touching.

The generator must be at least 5 feet from structures having combustible walls and/or other combustible materials.

Keep at least 3 feet of clearance on all sides of generator for adequate cooling, maintenance and servicing.

In the State of California a spark arrester is required by law (Section 4442 of the California Public Resources Code). Other states may have similar laws. Federal laws apply on federal lands. If you equip the muffler with a spark arrester, it must be maintained in effective working order.

Jump Start Procedure

If generator’s starting battery fails, use following instructions to jump start generator.You can jump start generator using any 12 Volt automotive or utility style storage battery.

1.Unscrew fuse holder and remove generator’s 10 Amp in-line fuse (Figure 8).Verify fuse is good or replace with a known good fuse. Reinstall fuse in fuse holder.

Figure 8 — In-Line Fuse

9

Page 9
Image 9