BSPP Generator

3.Slide a wheel over the axle.

NOTE: Be sure to install both wheels with the air pressure valve on the outboard side.

4.Slide a flat washer over the axle and place the e-ring onto the groove in the axle.

5.Place one end of the needle nose pliers on the bottom of the axle and the other end of the pliers on top of the e-ring. Seat the e-ring by pressing the pliers closed.

Refer to engine owner’s manual and follow oil recommendations and instructions.

NOTE: Check oil often during engine break–in. Refer to engine owner’s manual for recommendations.

NOTE: The generator assembly rotates on a prelubricated and sealed ball bearing that requires no additional lubrication for the life of the bearing.

6.Repeat step 3 through 5 to secure second wheel.

7.Remove the temporary blocks.

8.Attach the vibration mounts to the support leg with 1/4-20 x 3/4” capscrews and 1/4-20 lock nuts.

9.To aid support leg assembly, rest generator on cradle, engine end down. Remove the existing hardware from the left unit vibration mount with 13mm wrench. Use the same hardware to attach the support leg.

10.Attach the other side of the support leg with a M8 x 20 mm cap screw and M8 lock nut. Rest generator on wheels and support leg.

11.Attach handle to bracket on right side of generator frame (viewing unit from front), as shown in Figure 1, with a 50 mm capscrew, flat washers, nylon washers, and M8 lock nut.

NOTE: DO NOT overtighten. Handle must be able to move up and down freely.

12.Loop handle pin on generator frame just above handle bracket.

13.Raise handle and insert handle pin to move generator.

14.Check each fastener to ensure it is secure and the tires are inflated between 15-40 PSI.

BEFORE STARTING THE ENGINE

Add Fuel

NOTE: This gasoline engine is certified to operate on

gasoline. Exhaust Emission Control System: EM (Engine Modifications).

WARNING

Fuel and its vapors are extremely flammable and explosive.

Fire or explosion can cause severe burns or death.

WHEN ADDING FUEL

Turn generator OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

Fill fuel tank outdoors.

DO NOT overfill tank. Allow space for fuel expansion.

Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.

DO NOT light a cigarette or smoke.

1.Use clean, fresh, regular UNLEADED fuel with a minimum of 85 octane with equipment. DO NOT use fuel which contains Methanol. DO NOT mix oil with fuel.

2.Clean area around fuel fill cap, remove cap.

3.Slowly add regular unleaded fuel to fuel tank. Be careful not to fill above the baffle.This allows adequate space for fuel expansion (Figure 2).

Add Engine Oil

• Place generator on a level surface.

CAUTION

Any attempt to crank or start the engine before it has been properly filled with the recommended oil will result in equipment failure.

Refer to engine manual for oil fill information.

Damage to equipment resulting from failure to follow this instruction will void warranty.

Figure 2 — Typical Fuel Expansion Space

TANK

Baffle

FUEL

4.Install fuel cap and wipe up any spilled fuel.

7

Page 7
Image 7
Briggs & Stratton PRO4000 owner manual Before Starting the Engine, Add Fuel, Add Engine Oil, When Adding Fuel

PRO4000 specifications

The Briggs & Stratton PRO4000 is a dependable and powerful generator designed to meet the needs of both residential and professional users. With a robust build and advanced technology, it offers an excellent solution for powering essential appliances during outages or for use at worksites.

One of the standout features of the PRO4000 is its impressive peak power output of 4000 watts, providing ample energy for multiple devices. This makes it an ideal choice for running refrigerators, sump pumps, or power tools simultaneously. The generator's continuous running wattage capacity ensures a steady power supply, allowing users to maintain their usual lifestyle even in emergencies.

The PRO4000 is equipped with a reliable Briggs & Stratton engine, renowned in the industry for its durability and efficiency. The engine employs OHV (Overhead Valve) technology, which enhances performance and fuel efficiency while reducing emissions. This means users can operate the generator longer on a single tank of fuel, making it economical and environmentally friendly.

Portability is another significant feature of the PRO4000. It is designed with a compact frame and comes with heavy-duty wheels and a foldable handle. This allows for easy transportation across various terrains, making it suitable for camping trips, construction sites, or any outdoor activities where temporary power is required.

Safety is a priority with the PRO4000. It integrates advanced safety features like overload protection that automatically shuts off the generator to prevent damage, ensuring it runs smoothly and safely. The generator also incorporates a low oil shutdown feature that protects the engine from damage by shutting down when oil levels are too low.

User-friendly controls make the PRO4000 accessible for anyone to operate. The generator features clearly marked outlets for easy connection of devices, and an easy-to-read fuel gauge allows users to monitor fuel levels without opening the tank.

In summary, the Briggs & Stratton PRO4000 stands out with its powerful performance, reliable engine technology, portability, and safety features. Whether for home use during power outages or for commercial applications, the PRO4000 offers the versatility and reliability that users can depend on. It is an investment that ensures peace of mind and preparedness for whatever challenges come your way.