BSPP Generator

USING THE GENERATOR

System Ground

The generator has a system ground that connects the generator frame components to the ground terminals on the AC output receptacles.The system ground is connected to the AC neutral wire (see “Equipment Description”, earlier in this manual).

Special Requirements

There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction.

In some areas, generators are required to be registered with local utility companies.

If the generator is used at a construction site, there may be additional regulations which must be observed.

Connecting to a Building’s Electrical System

Connections for standby power to a building’s electrical system must be made by a qualified electrician.The connection must isolate the generator power from utility power, and must comply with all applicable laws and electrical codes.

DANGER

Generator produces powerful voltage.

Failure to isolate generator from power utility can result in death or injury to electric utility workers due to backfeed of electrical energy.

When using generator for backup power, notify utility company. Use approved transfer equipment to isolate generator from electric utility.

Use a ground fault circuit interrupter (GFCI) in any damp or highly conductive area, such as metal decking or steel work.

DO NOT touch bare wires or receptacles.

DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.

DO NOT operate generator in the rain.

DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.

DO NOT allow unqualified persons or children to operate or service generator.

Generator Location

Generator Clearance

DANGER

Running generator gives off carbon monoxide, an odorless, colorless, poison gas.

Breathing carbon monoxide will cause nausea, fainting or death.

Operate generator ONLY outdoors.

Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes or other openings.

DO NOT operate generator inside any building or enclosure, including the generator compartment of a recreational vehicle (RV).

The generator must be at least 5 ft. (152 cm) from structures having combustible walls and/or other combustible materials. Leave at least 3 ft. (92 cm) all around generator including overhead, for adequate cooling, maintenance and servicing.

Place generator in a well ventilated area, which will allow for removal of deadly exhaust gas. DO NOT place generator where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building. Ensure exhaust gas is kept away from any windows, doors, ventilation intakes or other openings that can allow exhaust gas to collect in a confined area (Figure 3). Prevailing winds and air currents should be taken into consideration when positioning generator.

Figure 3 — Generator Clearance

Typical Generator Shown

Exhaust Port

8

Page 8
Image 8
Briggs & Stratton PRO4000 owner manual Using the Generator, System Ground, Connecting to a Building’s Electrical System

PRO4000 specifications

The Briggs & Stratton PRO4000 is a dependable and powerful generator designed to meet the needs of both residential and professional users. With a robust build and advanced technology, it offers an excellent solution for powering essential appliances during outages or for use at worksites.

One of the standout features of the PRO4000 is its impressive peak power output of 4000 watts, providing ample energy for multiple devices. This makes it an ideal choice for running refrigerators, sump pumps, or power tools simultaneously. The generator's continuous running wattage capacity ensures a steady power supply, allowing users to maintain their usual lifestyle even in emergencies.

The PRO4000 is equipped with a reliable Briggs & Stratton engine, renowned in the industry for its durability and efficiency. The engine employs OHV (Overhead Valve) technology, which enhances performance and fuel efficiency while reducing emissions. This means users can operate the generator longer on a single tank of fuel, making it economical and environmentally friendly.

Portability is another significant feature of the PRO4000. It is designed with a compact frame and comes with heavy-duty wheels and a foldable handle. This allows for easy transportation across various terrains, making it suitable for camping trips, construction sites, or any outdoor activities where temporary power is required.

Safety is a priority with the PRO4000. It integrates advanced safety features like overload protection that automatically shuts off the generator to prevent damage, ensuring it runs smoothly and safely. The generator also incorporates a low oil shutdown feature that protects the engine from damage by shutting down when oil levels are too low.

User-friendly controls make the PRO4000 accessible for anyone to operate. The generator features clearly marked outlets for easy connection of devices, and an easy-to-read fuel gauge allows users to monitor fuel levels without opening the tank.

In summary, the Briggs & Stratton PRO4000 stands out with its powerful performance, reliable engine technology, portability, and safety features. Whether for home use during power outages or for commercial applications, the PRO4000 offers the versatility and reliability that users can depend on. It is an investment that ensures peace of mind and preparedness for whatever challenges come your way.